Deciphering error codes and malfunctions of Ballu air conditioners. Gree: error codes and fault codes gree cassette type air conditioner error codes

AUX, DAX, Renova, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu(Daihatsu), Vitek, digital display for air conditioner series fault:

  • Display mode = E4
  • Priority level display = 1 Non-mitsubishi52_63_71he-s power supply failure = Plastic temp sensor is abnormal.
  • Display mode = E1 Priority level display = 2
  • Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = E3 Priority level display = 3
  • Power supply failure = Copper temperature sensor abnormal (open, no signal) Display mode = E2 Priority level display =
    4

2. H series, AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu(Daihatsu), Renova (except KFR-25G/H) h3 HA HB series fault display:

  1. Power supply failure = PG motor feedback abnormal
  2. Priority level display = 1 Power supply failure = Plastic temp sensor abnormal Display mode = Timer LED blinks 1 time every 8 seconds
  3. Priority level display = 2 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds
  4. Priority level display = 3 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 1 time every 1 second
  5. Priority level display = 4

3. Series H (Y) air conditioner model remote display, removable panel AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu:

  1. Power supply failure = Motor feedback PG abnormal Display mode = Timer LED blinks 4 times every 8 seconds Priority level display = 1
  2. Power supply failure = Plastic temp sensor. abnormal Display mode = Timer LED flashes 1 time every 8 seconds Priority level display = 2
  3. Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds Priority level display = 3
  4. Power supply failure = Copper temperature sensor abnormal (open, no signal) Display mode = Timer LED flashes 1 time every 1 second Priority level display = 4

4. E. E. E. EU EZ EAA EAD EL HS1 HSZ HL1 HLZ P P1 ZZ CZ digital display air conditioner series AUX, DAX, Renova, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu(Daihatsu), Troubleshooting:

AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu power supply failure = Motor feedback PG abnormal Display mode = E4 Priority level display = 1

E1 or EL - as a common nutrition mistake.

Power supply failure or, in Russian, mains voltage< 210 В (сработала защита – токовая нагрузка) = Датчик темп ненормально Режим отображения = E1 Отображение уровня приоритета = 2

E1 is a fairly common mistake, I just encountered it yesterday.

    The reasons for E1 are obvious - insufficient voltage in the network< 210 В. При пуске компрессора происходит дополнительная просадка напряжения, токовая нагрузка max.
    Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = E3 Priority level display = 3

1

1

5. All other E series except EA EU E.M.E.U.Z. EAA EAD:

Power supply failure = PG motor feedback abnormal

Display mode = Timer LED blinks 4 times every 8 seconds

Priority level display = 1 Power supply failure = Plastic temp. abnormal Display mode = Timer LED blinks 1 time every 8 seconds

Priority level display = 2 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds Priority level display = 3

6. QA QB QD digital display of AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu, Vitek, Renova air conditioners - malfunctions, error codes:

  • Power supply failure = PG motor feedback abnormal Display mode = E4
  • Priority level display = 1 Power supply failure = Plastic temp sensor abnormal Display mode = E1
  • Priority level display = 2 Power supply failure = Copper temperature sensor abnormal
  • Display mode = E3 Priority level display = 3 Power supply failure = overcurrent oprotection
  • Display mode = E6 Priority level display = 4

1

1

7. QC QQ light display air conditioner series fault:

  • Power supply failure = PG motor feedback abnormal
  • Display mode = Timer LED blinks 4 times every 8 seconds Priority level display = 1 Power supply failure = Plastic temp sensor abnormal
  • Display mode = Timer LED blinks 1 time every 8 seconds Priority level display = 2 Power supply failure AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu = Copper temperature sensor abnormal
  • Display mode = Timer LED blinks 3 times every 8 seconds Priority level display = 3 Power supply failure = over current oprotection
  • Display mode = Timer LED blinks 6 times every 8 seconds Priority level display = 4

1

1

8. Display faults of 18000BTU ~ 24000BTU, AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu, Renova series - wall mounted air conditioner series:

  • Numbers for digital tube displays:
  • Power supply failure = PG motor feedback abnormal
  • Display mode = Timer LED blinks 1 time every 8 seconds Priority level display = 2
  • System errors = turns off Power supply failure = Plastic temp sensor abnormal Display mode =
  • Timer LED blinks 2 times every 8 seconds Priority level display = 3 System errors = turns off
  • Power supply failure = Copper temperature sensor Abnormal Mode display = Timer LED blinks 8 times every 8 seconds Priority level display = 4
  • System errors = not turning off Digital tube displays: Power supply failure = PG motor feedback abnormal Display mode = E1
  • Priority level display = 2 System errors = turns off Power supply failure = Plastic temp sensor abnormal Display mode = E3
  • Priority level display = 3 System errors = turn off Power supply failure = Copper temperature sensor abnormal Display mode = E2 Priority level display = 4
  • System errors = does not turn off

With Gree air conditioners and split systems, repairs are easier than with hi-fay series models.

Self-diagnosis of Gree air conditioners

What explains this, the layman asks?

The explanation is simple Gree: codes. On Gree air conditioners and split systems, there are not many protection system sensors. Those. everything is simplified.

  • Internal self-diagnosis of Gree air conditioners unified and almost identical in error positions to inexpensive air conditioners, such as Pioneer, General Climate, Lessar and others.

You will laugh, but for example, the catalog of Supra air conditioners has not even changed the name of the outdoor unit, perhaps there are not enough skills in Photoshop, perhaps they did not consider it necessary.

In a word, how were Supra air conditioners certified in Russia? It's a mystery to me. Supra Catalog!! In faith. Heh...

Self-diagnosis of Gree air conditioners is, -

  • high pressure protection
  • protected from freezing of the evaporator,
  • Compressor overload protection,
  • Errors in switching the air conditioner during installation, confusing wires,
  • And errors of temperature sensors of the evaporator and condenser.

Everything, agree not much. Gree, like an air conditioner, is functionally simple, so there are not many error codes.
There are drawbacks to this simplification - these are weak control board varistors, insufficient smoothing

Error codes table, continued.

currents during voltage surges. A trifle, but it must be borne in mind when repairing air conditioners Gree and their analogues.

Example: country house. The owners, leaving the dacha, usually de-energize the building with a common switch.
Those. extinguished and everything, calmed down. We arrived ... They turned on the light with the same switch, but the air conditioner, refrigerator, or other household appliances did not work. Why? The answer is simple.

When the power is turned on with a load, current and voltage surges occur.

Varistors that smooth out voltage surges cannot cope with the current load and burn out, burn well with smoke and soot, in the absence of a protective sheath, as a rule, together with the fuse of the control board of the indoor unit of the split system.

There are "specialists" who use wire when burning a fuse. Can you do that? It is possible, but then, in addition to the varistors, the control board, the fan motor of the indoor unit will also burn out, and ... it rushed up to the compressor windings of the outdoor unit of the air conditioner.

Fireworks at the cottage. - Expensive repairs.

Troubleshooting and breakdowns of the air conditioner, Gree: codes, as usual, we start with ...

- refrigeration circuit malfunctions,

- malfunctions of the electrical part, system e-mail. power supply and air conditioning control.
Source:

Error map, mapping. Primary diagnostics of the system.

GREE Semi-industrial, industrial air conditioners, - error codes.

Error Code = E1
Compressor, pressure surges (beep).

Error Code = E2
Faulty coil

Error code = E3
Low pressure air conditioning compressor activated (beep)

Error code = F0
Faulty room temperature sensor.

Error code = F1
Incorrect sensor resistance.

Error code = F2

  • The temperature sensor of the outdoor unit of the air conditioner has tripped.

Error code = F3
Temperature sensor circuit open.

GREE Split air conditioners Error code...

The cause of the malfunction, - the refrigerant system is highly protected, - pressure.
code = E1

Gree LED blinks 1 time.
Indicator, - cooling =
Heating indicator =

The cause of the Gree malfunction is frost protection.
code = E2

Air conditioner start LED = LED blinks 2 times.
Indicator, - cooling =
Heating indicator =

Cause of the malfunction, - Compressor exhaust high temperature protection.
code = E4

Air conditioner start LED = flashes 4 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction, - AC overcurrent protection
code = E5

Air conditioner start LED = LED blinks 5 times
Indicator, - cooling =
Heating indicator =

The cause of the malfunction is a communication failure between the indoor unit of the air conditioner and the outdoor unit of the split system.
code = E6

Gree air conditioner start LED = blinks 6 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction, - Anti-high temperature protection
code = E8

Air conditioner start LED = flashes 8 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction, - No feedback internal engine fan
code = H6

Air conditioner start LED = flashes 11 times
Indicator, - cooling =
Heating indicator =

Cause of the malfunction, - Jumper cap faulty protection
code = C5

Air conditioner start LED = flashes 15 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction, - Closed ambient sensor open, no contact or short circuit
code = F1

Indicator, - cooling = LED flashes 1 time
Heating indicator =

Name of sensor malfunction or failure = Indoor tube open, no contact or short circuit
code = F2

Air conditioning start LED =
Indicator, - cooling = LED flashes 2 times
Heating indicator =

The cause of the malfunction, - the external ambient sensor is open, there is no contact or a short circuit
code = F3

Air conditioning start LED =
Indicator, - cooling = LED flashes 3 times
Heating indicator =

Cause of malfunction, - Outer tube sensor open, no contact or short circuit
code = F4

Air conditioning start LED =
Indicator, - cooling = flashes 4 times
Heating indicator =

Name = malfunction or failure of the exhaust sensor open, no contact or short circuit
code = F5

Air conditioning start LED =
Indicator, - cooling = LED flashes 5 times
Heating indicator =

Cause of malfunction, - Over load limit / frequency reduction
code = F6

Air conditioning start LED =
Indicator, - cooling = Blink 6 times
Heating indicator =

Cause of malfunction, - Over current limit / frequency output
code = F8

Air conditioning start LED =
Indicator, - cooling = flashes 8 times
Heating indicator =

The cause of the malfunction, - High exhaust gas temperature limit / frequency reduction
code = F9

Air conditioning start LED =
Indicator, - cooling flash = 9 times
Heating indicator =

The cause of the malfunction, - Overvoltage protection for Ru
code=PH

Air conditioning start LED =
Indicator, - cooling = flashes 11 times
Heating indicator =

Cause of the malfunction, - alternating current detection of faulty circuits
code = U5

Air conditioning start LED =
Indicator, - cooling = flashes 13 times
Heating indicator =

The cause of the malfunction, - Compressor reverse protection
code = U4

Air conditioning start LED =
Indicator, - cooling = flashes 14 times
Heating indicator =

The cause of the malfunction, - Over the compressor phase current protection
code = P5

Air conditioning start LED =
Indicator, - cooling = flashes 15 times
Heating indicator =

The cause of the malfunction is the inlet of the malfucntion by the sensor tube
code = b5

Air conditioning start LED =
Indicator, - cooling = flashes 19 times
Heating indicator =

The cause of the malfunction, - The open DC fan motor is defective.
code = L3

Air conditioning start LED =
Indicator, - cooling = flashes 21 times
Heating indicator =

Cause of the malfunction, - Output malfunction or breakage of the tube sensor
code = b7

Air conditioning start LED =
Indicator, - cooling = flash 22 times
Heating indicator =

The cause of the malfunction, - The compressor overload sensor is defective.
code=FE

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Defrosting
code=h3

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = LED blinks 1 time

The cause of the malfunction is static dust protection cleaning
code = H2

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = LED blinks 2 times

Cause of malfunction, - Compressor overload protection
code = H3

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = LED flashes 3 times

Cause of malfunction, - System abnormal protection
code = H4

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 4 times

The cause of the malfunction, - IPM protection
code = H5

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = LED flashes 5 times

Cause of malfunction - PFC protection
code=HC

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 6 times

Cause of malfunction, - Compressor step loss protection
code = H7

Air conditioning start LED =
Indicator, - cooling =
Heating indicator flash = 7 times

Cause of the malfunction, - Heating against high frequency temperature drop
code=HO

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 10 times

Cause of malfunction - Startup failure
code = Lc

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 11 times

Cause of malfunction, - Phase failure protection compressor
code = U2

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 12 times

Cause of the malfunction, - Phase current compressor faulty detection circuits
code = U1

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 13 times

Cause of malfunction, - Compressor degaussing protection
code=HE

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 14 times

The cause of the malfunction, - EEPROM loading is defective.
code=EE

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 15 times

The cause of the malfunction is a communication failure between motherboard and board drivers
code = P6

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 16 times

The cause of the malfunction is a malfunction of the charge capacitor
code=PU

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 17 times

The cause of the malfunction is the IPM of the sensor circuit is faulty.
code = P7

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 18 times

The cause of the malfunction, - IPM high-temperature protection
code = P8

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 19 times

Cause of the malfunction, - PN protection voltage drop
code = U3

Air conditioning start LED =
Indicator, - cooling = flashes 20 times
Heating indicator =

The cause of the malfunction is low voltage protection PN
code=PL

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 21 times

Cause of the malfunction, - The current detection circuit is faulty or the current sensor is faulty or broken
code = Rs

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

The cause of the malfunction, - Compressor phase failure protection
code = Ld

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction, - Compressor or rotary protection blocked
code=LE

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

The cause of the malfunction, - IPM is more than the temperature limit / frequency reduction
code=EU

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - 4-way reversal valve abnormal
code = U7

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

The cause of the malfunction is the shutdown of the exhaust gas temperature sensor
code = U8

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction, - AC zero voltage error detection
code = U9

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

The cause of the malfunction, - Over the tube frequency temperature difference
code=FA

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

Cause of the malfunction, - Anti-freeze limit / frequency reduction
code=FH

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

Models: brand air conditioner repair KFR-32GW/BP, KFR-45LW/D, KFR-3502GW/BP, KFR-2501GW, KFR-45LW, KFR-3301GW, KFR-3201GWCPU, KFR-2608GW/BP and other KFR series, PDF fail.

Both domestic and industrial air conditioning systems, for the most part, have self-diagnosis function. This function can work in automatic mode or in a special mode if there is a problem with the equipment. As a rule, information with error codes can be observed on the displays located on the indoor units of the split systems. Thanks to this data, malfunctions due to which malfunctions in the air conditioning system have occurred are precisely determined. To independently determine the causes of problems in devices from different manufacturers, you can use the lists of error codes for various air conditioners, provided below by brand name.

In LG air conditioning systems, the microprocessor, when a malfunction is detected, blocking the start of the unit, after which it gives signals by flashing the LED, which report the error code.

If the system has detected several problems, then the breakdown that has the smallest sequence number is induced first. After that, there is an indication of faults in ascending order. The table below shows the error codes for LG air conditioners and explains what each of them means.

You should know: the occurrence of similar errors can be triggered by unsatisfactory parameters electrical network, or an accidental failure that occurred in the electronics of the unit. Therefore, do not rush to immediately contact the service, but simply turn off the power to the device and check the electrical voltage. It is also necessary to make sure that the correct device operating mode. After these checks, you can turn on the machine. Most often, this method helps in solving this problem, and it no longer appears.

The set of symbols for faults detected by the microprocessor depends on the model of the unit. For LG air conditioners, there may be another indication - in the form of numbers and letters.

Evaporator unit faults:

Capacitor block defect designations:

Designations in LG Art Cool units:

Daikin

Daikins are pretty sophisticated equipment(from a technical point of view) and, in addition to the refrigeration unit, have electronic control boards, many various sensors and valves, power inverter and other components. If any component of the device fails, it is difficult to find the cause of the breakdown without a special function that allows you to diagnose the equipment. This procedure is carried out using the remote control, and the error codes of Daikin air conditioners in case of a malfunction of the unit can be seen on its display.

Daikin evaporator unit problems:





Faults in the system:

Other problems:


Panasonic

Panasonic air conditioner error codes are usually displayed on the display located on the wall-mounted (room) unit of the unit. They can be recognized by pressing the “CHECK” button on the remote control and holding it for at least 5 seconds.

Since only a hole is visible instead of a button on the remote control, you can use a paper clip to press the recessed button, if it is straightened, or a small carnation.

After the remote control enters the error checking mode of Panasonic air conditioners, point it towards the indoor unit of the device and by pressing the buttons designed to control the timer (“up” and “down” arrows), start to cycle through the codes, starting from “H00” and further, by order. If the fault code matches in the memory of the wall unit and on the remote control, you will hear sound signal. To exit the check mode, press the “CHECK” button again.

Explanation of values ​​for Panasonic units:



Toshiba

The remote control of Toshiba Ras cooling systems also has a “CHECK” button that activates the self-diagnosis of the unit.

Codes for malfunctions in Toshiba domestic air conditioning systems (Toshiba RAS-07S3KHS-EE / RAS-07S3AHS-EE, Toshiba RAS-10EKV-EE / RAS-10EAV-EE):

Also, these values ​​are applicable for RAS-10SKHP-ES, RAS-13SKHP-ES, RAS-13S2AH-ES, RAS-07S2AH-ES, RAS-10S2AH-ES, RAS-07SKHP-ES and others.

Toshiba Industrial Conder Trouble Codes:




Ballu

Ballu air conditioner error codes, as usual, are displayed on the display evaporator indoor unit. Every time you turn on climate technology The Baloo microprocessor performs self-diagnostics of the equipment and, in case of malfunctions, displays special symbols on a miniature screen.

Decryption for devices brand Ballu:

Gree

If, when the air conditioner is turned on, the self-diagnosis system detects a malfunction in any module of the device, then its start is instantly blocked. At the same time, all error codes of Gree air conditioners can be observed either on the screen of the remote control or on the display of the indoor unit of the unit.

List of malfunctions of Gree air conditioning units:


General Climate

Alphanumeric designations of problems that are highlighted on the remote control:

Errors that are displayed on the wall unit display(domestic) General Climate:

Some of the General Climate air conditioner error codes above allow the user to independently find the problem and fix it. In other cases, for example, if the def / fan (pre / def) indicator flashes, specialist assistance is required.

Samsung

To start self-diagnostics of Samsung equipment, you need to start the operation of the conder in test mode. To do this, hold the split system start button for 5 seconds. Error codes for Samsung air conditioners, when detected, are displayed on the display of the unit located indoors.

Malfunctions in the operation of Samsung split systems:


Mitsubishi

For troubleshooting in technology from Mitsubishi, it is necessary within 4 seconds. hold on the remote control (simultaneously) 2 buttons: “CHECK” and “SET”. When problems are detected, error codes for Mitsubishi Electric air conditioners are displayed on the display of the indoor unit or remote control.


In addition to the above errors of the Mitsubishi Electric air conditioner, there are generic error codes relating to different models of Mitsubishi Electric units:

  • error E6 or EE - problems were detected in the connection between the unit located outside and the indoor unit. There is no signal from the sensor, or a short circuit is detected;
  • code E5 - malfunctions were detected during the operation of the equipment, it is also necessary to check the electrical voltage in the network.

Hitachi

The tables below show the error codes for Hitachi air conditioners. In Hitachi units, malfunctions are determined by blinking indicators.

TCL

Error codes in TCL climate systems (air conditioners) can be deciphered using the table below (the number of LED flashes in 8 seconds means an error code).


ideas

In Idea units, all problems detected by the processor at startup are highlighted on the air conditioner display.

MDV air conditioners have a self-diagnostic system. This means that in the event of a malfunction, the air conditioner issues an error code. By the error code of the MDV air conditioner, it is quite easy to identify the problem.
This page lists different types of MDV hardware error codes:

ERROR CODES FOR HOUSEHOLD SPLIT SYSTEMS MDV
AURORA Series (MDSA)

Display Error value
E0
E1 EEPROM read error, indoor unit
E3 No indoor unit fan control
E4 Error on temperature sensor T1 (Troom)
E5 Error on sensor T2 (boiling)
EU Refrigerant leak
F1 Error on the T4 sensor (Outdoor block, Outside)
F2 Error on the TK sensor (Nar.blok, Tcondensation)
F3 Error on the T5 sensor (Nar.blok, Injection)
F4 EEPROM read error, outdoor unit
F5 No outdoor unit fan control
P0 IPM failure or overcurrent
P1 Supply voltage too low or too high
R2 Compressor overheating
P4 Inverter module error

FAIRWIND Series (MDSF)

LED operation LED Timer Display Error Code Meaning
Flashing 1 time Off E1
Flashes 2 times Off E2 Signal transition control error through 0
Flashes 3 times Off E3
Flashes 5 times Off E5 Thermistor error T1 indoor unit (air sensor)
Flashes 6 times Off E6 Indoor unit T2 thermistor error (pipe sensor)
Flashes 7 times Off E7 Outdoor unit TC thermistor error (24 and 28 kBTU only)
Flashes 2 times Glows EU Refrigerant leak detected
Flashes 8 times Off E8 reserve
Flashes 9 times Off E9 Interconnect Error (24 and 28 kBTU only)

Note: Depending on the model of the air conditioner, the error code may be displayed on the digital display or on the mode display LEDs.

ERROR CODES OF MULTI-SPLIT SYSTEMS MDV
Free Match outdoor units (MD*O-**HFN1)

Display Error value
E0 EEPROM checksum read error
E2 Interconnect error
E3 Communication error "control board - inverter board"
E4 Outdoor unit temperature sensor error
E5
E8 Outdoor unit fan speed control error
F1 Indoor unit A thermistor error
F2 Indoor unit B thermistor error
F3 Indoor unit With thermistor error
F4 Indoor unit D thermistor error
F5 Indoor unit E thermistor error
P1 P protection high (MD40-28HFN1, MD40-36HFN1, MD50-42HFN1)
R2 P protection low (MD40-28HFN1, MD40-36HFN1, MD50-42HFN1)
RZ Compressor current protection
P4 Protection for high discharge T
R5 Compressor overheating
R6 Inverter module failure
LP

Note: all error codes are automatically erased after 30 seconds after the error has been eliminated / disappeared, except for E2 / E3.

Indoor units of wall-mounted, duct and cassette types

Designations:
O-glows;
X-off;

Error code Description of the fault LED Timer LED operation
(flashing,
amount
once)
E0 EEPROM checksum read error X 1
E1 Interconnect error X 2
E3 Indoor fan speed control error X 4
E4 X 5
E5 X 6
HER Condensate level sensor error (sensor or level) X 8
F0 O 1
F1 O 2
F2 O 3
F3 O 4
F4 O 5
F5 O 6
F6 O 7
F7 Reserve O 8
F8 Reserve O 9
F9 Reserve O 10
P0 III 1
P1 Too low or too high voltage III 2
RZ Too low outdoor temperature III 4
P4 Compressor error (see outdoor unit) III 5
R5 Mode conflict III 6
R6 Low pressure protection III 7
EU Refrigerant leak detected X 7
E2 Synchronization error X 3
R2 Compressor overheating III 3

Cantilever indoor units

Designations:
O-glows;
X-off;
/// - blinks at a frequency of 2 Hz.

Description of the fault Timer Lamp Operation Lamp
(flashing, number of times)
EEPROM checksum read error X 1
Interconnect error X 2
Indoor fan speed control error X 4
T1 thermistor error (indoor unit) X 5
T2 thermistor error (indoor unit) X 6
Overcurrent (not all models) O 1
T4 thermistor error (outdoor unit) O 2
TK thermistor error (outdoor unit) O 3
T5 thermistor error (outdoor unit) O 4
EEPROM checksum read error (outdoor unit), not all models O 5
Fan speed control error (outdoor unit) O 6
T2B thermistor error (indoor unit) O 7
Malfunction of inverter module (refer to outdoor unit codes) III 1
Too low or too high voltage III 2
Too low outdoor temperature III 4
Compressor error (See outdoor unit) III 5
Mode conflict III 6
Low pressure protection III 7

ERROR CODES OF SEMI-INDUSTRIAL SPLIT SYSTEMS MDV
Outdoor units

Error content LED 1 LED 2 LED 3
Phase rotation III X X
No phase (A, B) III X X
No phase (C) X X X
Low pressure protection III III X
Over current X X III
Board failure III X III
Open or short circuit of the TZ sensor circuit X III III
Open or short circuit of the T4 sensor circuit X III X
Capacitor overheating protection III III III

Note: Slow blinking of LEDs 1, 2, 3 means that the system is in standby mode.

Indoor units of floor and ceiling (MDUE), duct (MDTB), cassette full-size (MDCD), cassette compact (MDCA3) types.

Protection or malfunction monitoring timer defrosting alarm error code
T air sensor X III X X E2
Refrigerant T sensor III X X X E3
Condensation sensor T (for 18 and 24 kBTU) X X III X E4
EEPROM read error III III X X E7
Exceeding the level of condensate in the sump X X X III E8
Refrigerant leak (if equipped) III X X III EU

Column type indoor unit (MDFM)

Error code Protection or malfunction
P4 Evaporator T protection
R5 High T condensation protection
P9 Cold air protection
E1 T air sensor
E2 Refrigerant T sensor
E3 Condensation sensor T
E6 Outdoor unit malfunction
HS Defrost mode is running
P0 No communication between indoor unit control board and display (J2, S4)
Midea LCAC DC Inverter Series
Internal Cassette 4-Way Models
Error running timer defrost alarm Description
E1 Led2
Quik
Flash
No communication between indoor and outdoor unit
E2 Led 1
Quik
Flash
Faulty - shorted or broken air temperature sensor
E3 Led 1
Quik
Flash
Faulty evaporator temperature sensor (connector CN12 on the board)
E4 Led 1
Quik
Flash
Faulty temperature sensor at the outlet of the evaporator (connector CN7 on the board)
HER LED 4
Quik
Flash
Drain pan overflow error
E0 Led 3 Quik
Flash
Mismatch of air conditioner models
E7 Led 1
Quik
Flash
Faulty PROM, need to replace the board (microcircuit) or firmware
Ed LED 4
Quik
Flash
The external unit is faulty, see errors for it

Aeronik error codes

Error codes for air conditioners Aeronik (Aeronik)

E1 - increased pressure in the discharge of the compressor;
E2 - freezing of the heat exchanger of the indoor unit has occurred;
E3 - the pressure in the compressor discharge has decreased;
E4 - the temperature of the discharge pipeline has increased;
E5 - operation of the compressor current relay;
F0 - there are malfunctions in the air temperature sensor inside
rooms, in the heat exchanger during indoor unit or ambient air in the outdoor unit;
F0 - There may also be a freon leak in the indoor unit.
E6 - there were malfunctions in switching;
E8 - the engine of the indoor unit is overloaded;
F1 - there are malfunctions in the temperature sensor in the heat exchanger;
F4 - there are malfunctions in the temperature sensor of the injected air
air room.
H1- is not an error. The air conditioner has switched to auto defrost mode.

Airwell Error Codes

Error codes for Airwell air conditioners (Airvel)



Akvilon error codes

Akvilon air conditioner error codes (Akvilon)

Possible mistakes

Monitor mode 1

(indicator on

display)

Monitor mode 2

(wiring controller)

Appearance order

Actions

Communication error

Shutdown

Drainage system error

The indicator lights up 4 times/8sec

Shutdown

Phase failure, phase failure or low voltage error

The indicator lights up 6 times/8sec

Shutdown

The indicator lights up 1 time/8sec

Shutdown

Indoor unit sensor anomaly (TE)

The indicator lights up 2 times/8sec

Shutdown

The indicator lights up 2 times/1sec

Continue work

Protection against internal overheating

Shutdown

Defrosting (not an error)

Operation indicator lights up

Continue work

Fault codes for power supply 380-415W

Suitable for 36000~60000BTU units, with 380-415W 3N, 50Hz power supply

Possible mistakes

Display mode1

(Panel indicator

display)

Display Mode 2

(indicator

errors on the control panel)

Display mode3

(controller

wires)

Appearance order

Actions

Communication error

Lights up 5 times and goes out after 2 seconds

Shutdown

Communication error with wire controller

Shutdown

Error drainage system

Lights up 4 times and goes out after 2 seconds

Shutdown

External protection(Phase loss)

Lights up 6 times and goes out after 2 seconds

Shutdown

External protection (discharge from overheating)

Lights up 10 times and goes out after 2 seconds

Shutdown

Defence from high pressure

Shutdown

Low pressure protection

Lights up 9 times and goes out after 2 seconds

Shutdown

Room temperature sensor anomaly (Air temperature)

Lights up 1 time and goes out after 2 seconds

Shutdown

Indoor unit (TE) sensor anomaly

Lights up 3 times and goes out after 2 seconds

Shutdown

Outdoor unit sensor anomaly (TW)

Lights up 2 times and goes out after 2 seconds

Lights up 2 times and goes out after 2 seconds

Continue work

Anomaly external sensor condensate temperature(TL)

Lights up 7 times and goes out after 2 seconds

Continue work

Temperature Sensor Discharge Anomaly(TP)

Lights up 8 times and goes out after 2 seconds

Continue work

Ballu Error Codes

Error codes for air conditioners Ballu (Balu)


E1 - short circuit or open circuit of the sensor responsible for the indoor unit.
E2 - short circuit or open circuit of the sensor responsible for the temperature of the condenser.
E3 - short circuit or open circuit of the sensor responsible for the temperature of the evaporator.
E4 - short circuit or open circuit of the sensor responsible for the indoor unit.
E6 - the protection of the external unit has tripped.
E8 - electrostatic filter clogged.
P4 - an error has occurred in the operation of the evaporator sensor due to high or
low temperature.
P5 - an error has occurred in the operation of the capacitor sensor due to high or
low temperature.
P6 - the defrost mode has been switched on or there has been a delay in operation
heat exchanger.

Carrier Error Codes

Error codes for Carrier air conditioners


2 - there were malfunctions of the temperature sensor in the room;
3 - there were malfunctions of the temperature sensor in the internal
heat exchanger;
6 - there were malfunctions in the operation of the reversing valve in the outdoor unit;
8 - there were malfunctions in the fan motor located in
indoor unit;
9 - no power supply of the indoor unit;
11 - there were malfunctions in the drainage pump;
12 - there was a software failure in the indoor unit;
13 - an error occurred in the configuration;
14 - signal lost in central system management;
15 - there were malfunctions of the temperature sensor in the internal
heat exchanger;
18 - there were malfunctions in the control of the outdoor unit;
20 - the position of the block is not recognized;
21 - there were malfunctions of the current sensor located in the outdoor unit;
22 - there were malfunctions of the temperature sensor in the outdoor
heat exchanger;
23 - there were malfunctions of the discharge temperature sensor;
24 - there were malfunctions in the operation of the fan in the outdoor unit;
26 - other malfunctions in the outdoor unit;
27 - the compressor located in the outdoor unit has blocked;
28 - the value of the discharge temperature is unacceptable;
29 - there were malfunctions in the compressor, located in the outdoor unit;
31 - there was an increase in pressure in the circuit of the outdoor unit.

Cooper&Hunter Error Codes

Error codes for Cooper & Hunter air conditioners (Cooper & Hunter)

Code E0 - excess lower threshold starting voltage. Starting the frequency controller.
Code E1 - overpressure. Starting the compressor protection system.
Code E2 - the threat of freezing of the indoor unit. Launching the protection system.
Code E3 - lowering the allowable pressure threshold. Starting the compressor protection system.
Code E4 - excess allowable temperature injection tube. Launching the protection system.
Code E5 - compressor overload. Launching the protection system.
Code E6 - connection / operation error of the signal or power cable.
Code E7 - the set modes of the split system do not match.
Code E8 - evaporator overheating. Launching the protection system.
Code E9 - start of the cold air protection system in thermal mode.
Code F0 - failure of the temperature discharge sensor.
Code F1 - failure of the evaporator temperature sensor.
Code F2 - failure of the condenser temperature sensor.
Code F3 - failure of the air temperature sensor in the system.
Code F4 - failure of the supercharger temperature sensor.
Code F5 - failure of the compressor discharge tube sensor.
Code F6 - condenser overheating.
Code F7 - there is not enough lubrication in the compressor crankcase.
Code F8 - the compressor is overloaded. Launching the protection system.
Code F9 - exceeding the maximum condenser temperature due to a decrease in fan speed during cooling. The compressor is overloaded.
Code FF - there is no power supply to one of the phases / an error in the operation of the phase monitor.
Code FA - condenser/evaporator superheat. Launching the protection system.
Code FH - Evaporator Frost Threat. Launching the protection system.
Code H0 - overheating protection is activated.
Code H1 - condenser defrost mode is activated.
Code H2 - an error in the operation of the electrostatic filter. Launching the protection system.
Code H3 - exceeding the permissible temperature of the compressor. Launching the protection system.
Code H4 - an error in the system.
Code H5 - start the protection system of the inverter unit IPM.
Code H6 - sensor malfunction. Lost return signal from fan motor.
Code H7 - the compressor is faulty.
Code H8 - the drainage system is overflowing. Start protection.
Code H9 - malfunction of the electric heater of the indoor unit.

Daikin error codes

Error codes for Daikin air conditioners (Daikin)


A0 - safety device tripped.
A1 - PCB failure.
A2 - the fan motor is blocked.
A3 - abnormal level of drainage.
A4 - malfunctions in the heat exchanger.
A5 - abnormal temperature in the heat exchanger.
A6 - the fan motor is overloaded.
A7 - Faulty shutter drive.
A8 - current overload of the device.
A9 - expansion valve is defective.
AA - engine overheated.
AH - air filter contamination.
AC - idling is fixed.
AJ - insufficient performance.
AE - weak water supply.
AF - humidifier defect detected.
C0 - the sensor is faulty.
C3 - the sensor responsible for the drainage system is faulty.
C4 - the sensor responsible for the temperature of heat exchanger 1 is faulty.
C5 - the sensor responsible for the temperature of heat exchanger 2 is faulty.
C6 - the fan motor is overloaded.
C7 - the sensor responsible for the blind drive is faulty.
C8 - the sensor responsible for the input current is faulty.
C9 - Faulty inlet air thermistor.
CA - the outlet air thermistor is defective.
CH - high level of pollution.
CC - humidity sensor is defective.
CJ - the temperature sensor located on the control panel is faulty.
CE - the radiation sensor is defective.
CF - the sensor responsible for high pressure is faulty.

Error codes for the outdoor unit of Daikin air conditioners (Daikin)

E0 - a protective device has tripped.
E1 - the printed circuit board located in the outdoor unit is faulty.
E3 - triggering of the sensor responsible for high pressure.
E4 - triggering of the sensor responsible for low pressure.
E5 - overheating relay or compressor motor overloaded.
E6 - the compressor motor is blocked.
E7 - the fan motor is blocked.
E8 - current overload detected.
E9 - the expansion valve is faulty.
AH - a pump blockage has occurred.
EJ - operation of an additional protective device.
EE - exceeded in the drainage system allowable level water.
EF - the unit responsible for the accumulation of heat is faulty.
H0 - general malfunction of the sensors.
H1 - the sensor responsible for the air temperature is faulty.
H2 - the sensor responsible for the electrical supply is faulty.
H3 - the sensor responsible for high pressure is faulty.
H4 - the sensor responsible for low pressure is faulty.
H5 - activation of the overload sensor or the compressor does not work.
H6 - activation of the blocking sensor or the compressor is overloaded.
H7 - activation of the blocking sensor or the fan is overloaded.
H8 - triggering of the sensor responsible for the input voltage.
H9 - triggering of the sensor responsible for the outdoor temperature.
HA - triggering of the sensor responsible for the outlet air.
HH - triggering of the sensor responsible for blocking the water pump.
HС - triggering of the sensor responsible for hot water.
HE - triggering of the sensor responsible for the drainage system.
HF - an accident has occurred in the heat storage unit.
F0 - actuation of devices No. 1 and No. 2, responsible for protection.
F1 - actuation of device No. 1, responsible for protection.
F2 - actuation of device No. 2, which is responsible for protection.
F3 - too high temperature in the discharge pipe.

Dantex Error Codes

Error codes for Dantex air conditioners (Danteks)


E1 - an error occurred in the non-volatile memory;
E2 - there was a zero crossing error;
E3 - no control of the fan speed of the indoor unit;
E4 - the overvoltage protection mode is in effect;
E5 - there is no contact with the control of an open temperature sensor;
E6 - there is no contact with the control of the evaporator temperature sensor.

Chillers Dantex (DN)

E0 - an error occurred in the operation of the water flow meter;
E1 - an error occurred when connecting the phases;
E2 - a communication error has occurred;
E3 - an error has occurred in the outlet water temperature sensor;
E4 - an error has occurred in the temperature sensor of the water at the outlet of
shell and tube heat exchanger;
E5 - an error in the operation of capacitor A;
E6 - an error in the operation of the capacitor B;

E8 - an error has occurred in the charge air temperature sensor;
E9 - an error occurred in the flowmeter;
EA - the main block revealed a decrease in the number of additional blocks;
EB - malfunctions of the frost protection system;
EC - failures in the operation of the drive controller;
ED - an error occurred in the control system and communication between the blocks;
Ed - operation of electrical protection;
EE - an error has occurred in the connection between the microprocessor and the control panel;
EF - an error occurred in the inlet water temperature sensor;
RO - overheating or increased pressure;

P2 - increased pressure or overheated air in system B;
P3 - the pressure in the system has decreased;
P4 - there was an overcurrent in system A;
P5 - there was an overcurrent in system B;
P6 - increased pressure in the condenser of system A;
P7 - increased pressure in the condenser of system B;
P8 - malfunctions in the operation of the compressor discharge temperature sensor in system A;
Pb - frost protection;
PE - the temperature in the heat exchanger has decreased;
F1 - errors in the work of permanent memory;
F2 - errors in the operation of wired controllers.

Elektrolux error codes

Error codes for Elektrolux air conditioners (Electrolux)


E1 - the pressure level is exceeded;
E2 - the indoor unit has frozen;
E3 - too low pressure level;
E4 - malfunctions of the compressor;
E5 - an overcurrent has occurred;
E6 - there is no connection between the indoor and outdoor units;
E7 - there was a conflict in the operating modes of the indoor units;
E8 - the fan of the indoor unit is overloaded;
E9 - the drainage bath is overflowing;
F0 - malfunctions in the operation of the temperature sensor in the indoor unit;
F1 - malfunctions in the operation of the temperature sensor inlet to the heat exchanger
in the indoor unit;
F2 - malfunctions in the operation of the temperature sensor in the middle part

F3 - malfunctions in the operation of the temperature sensor at the outlet of
heat exchanger in the indoor unit;
F4 - malfunctions in the operation of the ambient air temperature sensor;
F5 - malfunctions in the operation of the temperature sensor of the outdoor unit;
F6 - malfunctions in the operation of the temperature sensor inlet to the heat exchanger
in the outdoor unit;
F7 - malfunctions in the operation of the temperature sensor of the exit from
heat exchanger in the indoor unit;
F8 - malfunctions in the operation of the discharge temperature sensor of the first
compressor;
F9 - malfunctions in the operation of the discharge temperature sensor of the second
compressor;
FA - malfunctions in the operation of the crankcase temperature sensor of the 1st compressor;
FB - malfunctions in the operation of the crankcase temperature sensor of the 2nd compressor;
FC - malfunctions in the operation of the high pressure sensor;
FD - malfunctions in the operation of the low pressure sensor;
EH - malfunctions in the operation of the additional heater.

Fuji Error Codes

Error codes for Fuji air conditioners (Fuji)


E00 - an error occurred in the connection of the remote control with the indoor unit;
E01 - an error occurred in the connection between the indoor and outdoor modules;
E02 - malfunctions of the room temperature sensor;
E03 - a short circuit has occurred on the room temperature sensor;
E04 - an error occurred in the operation of the temperature sensor on the internal
heat exchanger;
E05 - a short circuit has occurred on the temperature sensor of the internal
heat exchanger;
E06 - an error occurred in the operation of the temperature sensor on the outdoor
heat exchanger;
E07 - a short circuit has occurred on the outdoor temperature sensor
heat exchanger;
E08 - supply is broken electrical energy;
E09 - there was an overflow of the tank intended for collecting condensate;
E0R - malfunctions in the operation of the temperature sensor of the outdoor unit;
E0B - a short circuit has occurred on the temperature sensor of the outdoor unit;
Е0С - opening of the temperature sensor on the drain pipe is required;
E0D - a short circuit has occurred on the temperature sensor of the drain pipe;
E0F - the output temperature is too high or too low;
E11 - malfunctions of the control board;
E12 - malfunctions of the fan of the indoor unit;
E13 - giving incorrect signals by the system;
E14 - error in non-volatile memory.

General Climate Error Codes

Error codes for General Climate air conditioners (General Climate)


E2 - short circuit or open circuit of the sensor responsible for the temperature of the internal
air.
E3 - short circuit or open circuit of the sensor responsible for the temperature of the evaporator.
E4 - short circuit or open circuit of the sensor responsible for the temperature of the condenser.
E5 - in progress drainage pump An error has occurred.
E6 - an error in the protection of the external unit.
E7 - An EEPROM error has occurred.
E8 - the overflow protection of the drain pan has tripped.

Gree Error Codes

Error codes for Gree air conditioners (Gri)


E1 - the compressor protection against too high pressure has tripped.
E2 - the frost protection of the indoor unit has worked.
E3 - the compressor protection against too low pressure has tripped.
E4 - the protection of the injection tube against high temperature has tripped.
E5 - the protection of the system or compressor against overloads has worked.
E6 - problems have been detected in the signal or power cables.
E7 - contradictions in the established mode.
E8 - the protection of the electric motor or evaporator against overheating has tripped.
E9 - protection against cold air entry during heating has worked.
E0 - protection of the frequency controller from too low starting
voltage.
H6 - no feedback from the fan motor.
F0 - the temperature discharge sensor is faulty.
F1 - the sensor responsible for the evaporator temperature is faulty.
F2 - the sensor responsible for the temperature of the condenser is faulty.
F3 - the sensor responsible for the air temperature in the system is faulty.
F4 - the sensor responsible for the temperature of the supercharger is faulty.
F5 - the sensor responsible for the compressor discharge pipe is faulty.
F6 - Capacitor overheating detected.
F7 - oil carryover from the compressor is detected.
F8 - protection of the system or compressor from overloads has worked.
F9 - the compressor protection against high temperatures has worked.
FF - no power in one of the phases or the phase monitor is faulty.
H1 - defrosting is in progress.
H2 - protection of the electrostatic filter has tripped.
H3 - protection against severe overheating has tripped.
H4 - A system failure has occurred.
H5 – IPM block protection operation.
H7 - malfunctions in the compressor.
H8 - operation of the drainage system protection against overflow.
H9 - electrical heater malfunctions.
H0 - overheat protection trip.
FA - operation of the condenser or evaporator protection against overheating.
FH - activation of the evaporator frost protection.

Green Error Codes

Error codes for Green air conditioners (Green)


U1 - Current phase fault, circuit detection for compressor. Flashes 13 times. During cooling and drying operation, the compressor will stop while the indoor fan is running. When running in heating mode, the full unit will stop. Replacement of the external control panel AP1.

U3 - Malfunction voltage dropping on the DC bus. Flashes 20 times. During cooling and drying operation, the compressor will stop while the indoor fan will run; When operating in heating mode, the full unit will stop.
The supply voltage is unstable.

U5 - Malfunction of the full unit of current detection. Flashes 13 times. During cooling and drying operation, the compressor will stop while the internal fan is running; During heating operation, the full block will stop the operation. There is a circuit malfunction on the outdoor units control panel AP1, please replace the outdoor unit control panel AP1.

U7 - Blinks 20 times. If this fault occurs during heating operation, the device will stop working. 1. The power supply voltage is lower than AC175V; 2. Wiring terminal 4V is loose or broken; 3. 4V will be damaged, please replace the cable.

U8 - Zero transition inspection circuit malfun-fiction Fan pin moto. Flashes 17 times every 3s Remote controller operation or
the control panel is available, but the units will not function. The discharging speed of the capacitor is slow, which lead to wrong decision of the controller. Zero crossing detection circuit of the main board abnorma. Refer to flowchar repair.

U9 - Zero crossing outdoor unit malfunction. Flashes 18 times. During cooling operation, the compressor will stop when the indoor fan is running; during heating, the device will not work. Replacement of the external control panel AP1.

Haier Error Codes

Error codes for Haier air conditioners (Haer)

E0 Violation of the condensate drain function.
E1 The compressor is pressurized.
E2 The heat exchanger of the indoor unit is covered with ice.
E3 Insufficient pressure in the compressor.
E4 Compressor overheating.
E5 Compressor disabled due to increased load.
E6 No communication between blocks.
E7 The indoor unit does not respond to commands from the remote control.
E8 Indoor unit motor overload.
F0 The temperature sensor in the room has turned off.
F1 The temperature sensor of the heat exchanger of the indoor unit has turned off.
F2 The temperature sensor of the heat exchanger of the outdoor unit has turned off.
F3 The outdoor temperature sensor has switched off.
F4 The temperature sensor on the air supply has switched off.
FF Power failure.

Hisense Error Codes

Error codes for Hisense air conditioners (Hysens)

Possible reasons faults:
1 Outdoor unit heat exchanger temperature sensor error a. Outdoor unit heat exchanger temperature sensor circuit open; b. Faulty outdoor unit heat exchanger temperature sensor; With. Faulty outdoor unit control circuit board
2 Compressor discharge temperature sensor error a. The temperature sensor circuit in the compressor discharge line is open; b. Faulty temperature sensor in the compressor discharge line; With. Faulty outdoor unit control circuit board
5 Integrated Power Module (IPM) protection trip a. Faulty integrated power module (IPM) circuit board; b. The fan of the outdoor unit is out of order; c. Faulty outdoor unit fan motor; d. Outdoor unit fan blocked; e. Condenser dirty; f. The installation instructions for the outdoor unit are not followed.
6 AC overvoltage or undervoltage protection tripped a. The voltage in the network is above or below the maximum permissible values; b. The power supply voltage of the unit is above or below the maximum permissible values
7 Communication error between indoor and outdoor units a. Breakage of the connecting cable; b. Connecting cable damaged; With. Incorrect connection or broken connection between the filter board and printed circuit board outdoor unit control
8 Overload protection device a. Fan motor failure; b. The evaporator and condenser are dirty; c. Blocked air intake and air outlet; d. Faulty printed control of the outdoor unit; e. Compressor defective
10 Communication error between two microcircuits (control and drive) in the printed circuit a. Poor cable connection b. Faulty outdoor unit PCB or drive circuit board;
11 Outdoor unit EEPROM memory error a. Poor soldering of the EEPROM chip; b. EEPROM chip installation error (wrong position); .EEPROM chip failure
12 Operation of the protection device at low outdoor temperatures a. This protection is triggered if the outdoor temperature drops below 15°C; b. Faulty outdoor temperature sensor; With. Faulty outdoor unit control PCB.
13 Safety device tripped due to overtemperature at a. Faulty temperature sensor in the compressor discharge line; b. Insufficient refrigerant charge in the system
14 Outside air temperature sensor error a. Open circuit of the outdoor temperature sensor; b. Faulty outdoor temperature sensor; With. Faulty outdoor unit control circuit board
15 Compressor thermal overload trip a. Compressor discharge temperature sensor circuit open b. Insufficient refrigerant charge in the system
16 Heat exchanger frost protection or overload protection operation during indoor unit heating operation a. Regular operation of the protection device in case of freezing of the heat exchanger or overloads; b. Indoor heat exchanger temperature sensor circuit open; c. Faulty indoor unit heat exchanger temperature sensor; d. Faulty indoor unit control circuit board; e. Refrigerant circulation disorder
17 Compensation device reactive power(PFC) a. Faulty reactive power compensation device; b. Faulty outdoor unit drive circuit board
18 DC compressor start error a. Incorrect connection or breakage of the compressor power cable; b. The circuit board of the integrated power module (IPM) of the outdoor unit is defective; c. Faulty outdoor unit control PCB d. Compressor defective
19 Compressor drive error a. Incorrect connection or breakage of the compressor power cable; b. The circuit board of the integrated power module (IPM) of the outdoor unit is defective; c. Faulty outdoor unit control PCB d. Compressor defective 7. Troubleshooting
20 Locked-rotor outdoor fan motor protection tripped a. Outdoor unit fan motor circuit open; b. Outdoor unit fan blocked; With. Faulty fan motor; d. Faulty outdoor unit control circuit board

Hitachi Error Codes

Error codes for Hitachi brand air conditioners (Hitachi)


01 - malfunction of the reversing valve or out of order
media temperature.
02 - the mode is activated, forcibly starting the external module.
03 - there is no communication between the external and internal module.
04 - equipment malfunctions, you should pay attention to the readings
other indicators.
06 - violations were detected in the operation of the pump, which pumps out condensate.
07 - requires manual start of the pump.
08 - engine functions are violated.
09 - no communication with the PCB thermistor.
10 - incorrect fan operation.
13 - PCB does not function.

Hyundai error codes

Error codes for Hyundai air conditioners (Hyundai)

0 – error in non-volatile memory;
E1 - an error occurred in the connection of the blocks: indoor and outdoor;
E2 - malfunctions of the sensor of the outdoor unit;
E3 - malfunctions of the fan motor of the indoor unit;
E4 - an open (short circuit) of the indoor air temperature sensor has occurred;
E5 - there was a break (short circuit) of the evaporator temperature sensor;
EC - A coolant leak has occurred.

Jax error codes

Jax Air Conditioner Error Codes (Jax)


E2 - there were malfunctions in the indoor air temperature sensor;
E3 - there are malfunctions in the evaporator temperature sensor;
E4 - there are malfunctions in the condenser temperature sensor;
E5 - an error occurred in the operation of the drainage pump;
E6 - protection worked during outdoor unit;
E7 - failures in non-volatile memory;
E8 - the drain pan is full.

Kentatsu Error Codes

Error codes for Kentatsu air conditioners (Kentatsu)


E1 - there is no contact with the air temperature sensor in the internal
block;
E2 - there is no contact with the temperature sensor of the evaporator;

E4 - there is no contact with the outdoor air temperature sensor;
E5 - there is no contact between the indoor and outdoor unit;
E6 - warning of overheating or freezing of the outdoor module;
E10 - there was a pressure failure in the compressor;
E13 - no electricity is supplied due to tangled wires;
E14 - supply of electricity to the wrong phase;
P4 - the evaporator has overheated;
P5 - the capacitor has overheated;
P7 - exceeding the temperature level in the compressor;
P9 - frost protection turned on;
P10 - the value of the air at the outlet is incorrect;
P11 - the air intake pressure exceeds allowable norms;
P12 - supply of high voltage current;
HS - defrosting of the outdoor module is in progress.
EC - Freon leak.

Models Kentatsu (Kentatsu) KSGH/KSRH

E1 - errors occurred in non-volatile memory;
E2 - there was a failure in the transformation process zero cycle;
E3 - incorrect rotation of the fan;
E4 - supplying too high voltage to the compressor;
E5 - there was a violation of communication with the temperature sensor of the air inside;
E6 - there was a communication failure with the evaporator temperature sensor.

Models Kentatsu (Kentatsu) KSFU/KSRU

P4 - the evaporator of the indoor module has overheated;
P5 - the condenser of the outdoor module has overheated;
P9 - thawing is in progress;
E1 - no voltage to temperature sensors;
E2 - there is no connection with the temperature sensor of the evaporator;
E3 - there is no contact with the temperature sensor of the condenser;
E6 - there are malfunctions in the external module.

Channel type air conditioners

E0 - malfunctions of the temperature sensor in the room;
E1 - there were malfunctions in the operation of the evaporator temperature sensor;
E2 - there are malfunctions in the temperature sensor of the external module;
E3 - there is no connection with the outdoor module;
E4 - there were malfunctions in the condenser pump;
E5 - errors in non-volatile memory;
E6 - the condensate collection pan is full.

Lessar Error Codes

Error codes for Lessar air conditioners (Lessar)


E0 - an error has occurred in the flow sensor;
E1 - wrong phase sequence;
E2 - a communication error has occurred;
E3 - an error has occurred in the direct water temperature sensor;
E4 - an error has occurred in the temperature sensor of the shell-and-tube heat exchanger;
E5 - an error has occurred in the temperature sensor of the condenser pipe A;
E6 - an error has occurred in the temperature sensor of the condenser pipe B;
E7 - an error has occurred in the outdoor air temperature sensor;
E8 - an error has occurred in the compressor discharge temperature sensor
systems A;
E9 - an error has occurred in the flow temperature sensor;
EA - there was a loss of communication with the slave units;
P0 - pressure or temperature in system A is exceeded;
P1 - pressure in system A has decreased;
P2 - the pressure or temperature in the system B is exceeded;
P3 - pressure in system B has decreased;
P4 - there was an excess of current in system A;
P5 - there was an excess of current in system B;
P6 - the condensation temperature in system A is exceeded;
P7 - the condensing temperature in system B is exceeded;
P8 - temperature rise in the compressor;
Pb - frost protection.

LG error codes

Error codes for LG air conditioners (Algy)


01 - there was a short circuit in the sensor responsible for the air temperature,
or broken circuit.
02 - a short circuit occurred in the sensor responsible for the temperature
evaporator, or open circuit.
03 - a bad connection between the drive console and
indoor unit.
04 - an error occurred in the operation of the drain pump or float
sensor responsible for the level of condensate.
05 - fixed error of interconnection of internal and external
blocks.
06 - a short circuit occurred in the temperature sensor responsible for the outdoor
block or open circuit.
07 - indoor multi-system units operate in different modes.
HL - the float sensor has opened.
CL - child lock is activated.
Po - the device operates in jet cool mode.

MDV error codes

Error codes for air conditioners MDV (MDV)


Free Match Series
Error indication on the indoor unit


Fault codes on the outdoor unit

Universal outdoor unit

Models with three-phase power supply with a capacity of 30, 36, 48, 60 Btu / h



Midea Error Codes

Error codes for Midea air conditioners (Midea)


E0 - an error occurred in the non-volatile memory of the indoor unit.
E1 - an error occurred in the connection of the outdoor and indoor units.
E2 - an error occurred during the transition through zero.
E3 - an error occurred during the operation of the fan motor.
E4 - short circuit or open circuit of the sensor responsible for the temperature of the internal
air.
E5 - short circuit or open circuit of the sensor responsible for the temperature of the evaporator.
EC - a refrigerant leak has been detected.

Mitsubishi Electric Error Codes

Mitsubishi Electric Air Conditioner Error Codes (Mitsubishi Electric)


P1 - an error of sensors at the input is fixed.
P2 - an error in the operation of the sensor responsible for the TH5 heat exchanger.
P4 - the drain pan is full or the CN4F sensor has broken.
P5 - An error has occurred in the drain pump.
P6 - overheating or freezing has occurred.
P9 - an error in the operation of the sensor responsible for the TH2 heat exchanger.
PA - the compressor is forced to stop.
E0, E3 - lost connection with the control panel.
E1, E2 - problems in the control board.
E9, EE - there is no communication between the outdoor and indoor unit.
U1. Ud - overheating protection has tripped, or the 63H sensor has fixed
high pressure.
U2 - low pressure in the supercharger, not enough refrigerant.
U3, U4 - short circuit or open circuit in the temperature sensor of the outdoor unit.
U5 - the temperature of the condenser does not correspond to the norm.
U6 - a forced stop of the compressor or a malfunction has been detected
power module.
U7 - lack of refrigerant or low pressure in the supercharger.
U8 - the motor of the fan installed on the outdoor unit has stopped.
U9, UN - low or high supply voltage, or malfunctions in
current sensor.
UF - the compressor is stuck or a current overload is detected.
UP - compressor stopped due to overload.
Fb - problems in the control board of the external unit.

Mitsubishi Heavy error codes

Error codes for Mitsubishi Heavy air conditioners (Mitsubishi Heavy)


E1 - there was a malfunction in the printed circuit board of the indoor unit or there were
malfunctions in the control panel;
E2 - there was a duplication of addresses of indoor units;
E3 - the address of the outdoor unit is incorrect;
E5 - there were malfunctions in the control board of the outer side;
E6 - an open (short circuit) of the evaporator sensor has occurred;
E7 - there was a break (short circuit) of the sensor of the indoor unit;
E8 - an evaporator overload has occurred;
E9 - an error in the operation of the drainage pump;
E10 - more than 16 blocks are connected to the control panel;
E11 - more than 1 block is connected to the control panel when the address is occupied;
E12 - errors in the address settings;
E14 - incorrect settings of the master and slave connections were made;
E16 - there were malfunctions in the operation of the fan of the indoor unit;
E28 - there were malfunctions in the sensor of the control panel;
E30 - an error occurred in the connection of the outdoor and indoor units;
E31 - incorrect address settings;
E32 - a wire break has occurred or the phase sequence has been incorrectly performed;
E33 - there was a break in the winding of the wire;
E34 - the phase of the winding has opened;
E35 - malfunctions in the operation of the sensor or an increase in temperature in
condenser;
E36 - there was a deviation in the temperature of the outlet air above the norm;
E37 - there were malfunctions in the condenser temperature sensor;
E38 - there were malfunctions in the outdoor air temperature sensor;
E39 - there were malfunctions in the temperature sensor of the discharge pipe;
E40 - there was an increase in pressure in the system;
E49 - a decrease in pressure has occurred or the refrigerant is not enough;
E53 - there were malfunctions in the thermistor of the suction pipe;
E54 - the low pressure sensor is disconnected;
E55 - there are malfunctions in the temperature thermistor inside the compressor;
E56 - there were malfunctions or a break in the temperature sensor of the power
transistor;
E57 - insufficient amount of coolant;
E59 - the compressor does not start;
E60 - an error occurred in the positioning of the compressor;
E63 - an emergency shutdown of the indoor unit has occurred.

Neoclima error codes

Error codes for Neoclima air conditioners (Neoclima)

Code E0 - an error in connecting the indoor and outdoor units.
Code E1 - an error in the operation of the indoor unit. Disruption of communication with the controller.
Code E2 - an error in the operation of the temperature sensor.
Code E3 - the temperature sensor of the condenser tube is defective.
Code E8 - violations in the operation of the heating system.
Code F0 - an error in the operation of the internal fan.
Code F2 - the external protection system has worked.
Code F3 - protection in the high pressure system has tripped.
Code F4 - protection in the low pressure system has tripped.
Code F5 - water overflow protection has tripped.
Code F8 - protection against overheating of the outdoor unit has worked.
Code F9 - incorrect phase sequence. Error in the system.
Code P4 - the compressor of the inverter air conditioner is faulty.
Code P6 - an error in the operation of the outdoor unit EEPROM.

Panasonic error codes

Error codes for Panasonic brand air conditioners (Panasonic)


H00 - no problems found.
H11 - no communication between the outdoor and indoor unit or malfunction
control boards.
H12 - the power of the indoor units does not match the outdoor one.
H14 - short circuit of the air sensor.
H15 - short circuit of the sensor responsible for the temperature of the compressor.
H16 - lack of freon in the external unit or the current circuit is broken
board transformer.
H17 - breakage of the sensor responsible for the temperature on the tube,
designed to dry the refrigerant.
H19 - the board, fan motor or connectors are jammed
wires.
H21 - Faulty or clogged float sensor drainage system.
H23 - sensor 1 is broken, which is responsible for the temperature of the evaporator.
H24 - sensor 2 is broken, which is responsible for the temperature of the evaporator.
H25 - malfunctions in the ionization unit or internal board.
H26 - the ionizer has failed.
H27 - short circuit of the sensor responsible for the temperature of the outdoor air.
H28 - short circuit of the sensor responsible for the temperature of the condenser.
H30 - the sensor responsible for the discharge temperature is broken.
H32 - short circuit of the sensor responsible for the temperature of the condenser at the outlet.
H33 - An error has occurred in the interconnection.
H34 - short circuit of the sensor responsible for the temperature of the module heatsink.
H35 - a pump malfunction or drain blockage has been detected.
H36 - short circuit of the sensor responsible for the temperature of the gas pipe.
H37 - short circuit of the sensor responsible for the temperature of the liquid tube.
H38 - a discrepancy between the outdoor and outdoor unit has been detected.
H39 - freon circuits and wires are mixed up, or does not work
solenoid valve.
H41 - wires are connected incorrectly.
H50 - malfunctions in the board or fan motor.
H51 - The nozzle is clogged.
H52 - the limiter switch is defective.
H58 - Patrol Sensor unit is defective.
H64 - the sensor responsible for high pressure is faulty.
H97 - malfunctions in the compressor motor or indoor unit board.
H98 - Faulty overheating protection.
H99 - evaporator freezing has been detected.
F11 - the four-way valve does not work correctly.
F17 - the indoor unit is frozen.
F90 - the compressor winding is broken.
F91 - the refrigeration circuit is not working correctly.
F93 - the compressor winding is broken.
F94 - high pressure blower protection does not work.
F95 - the heat exchanger of the outdoor unit has overheated.
F96 - the power module has overheated.
F97 - Compressor temperature exceeded.

Pioneer error codes

Error codes for Pioneer air conditioners (Pioneer)

Air conditioner error code Pioneer Yellow diode Green diode
Red diode

Deciphering Pioneer Air Conditioner Errors
E0 * The function of the discharge temperature sensor is broken
E6 * The function of the capacitor temperature sensor is broken
E6 * The function of the outdoor air temperature sensor is broken
E1 * The function of the temperature sensor in the room is broken
E2 * The function of the evaporator temperature sensor is broken
E3 m m m Indoor unit fan broken
E4 m * IPM system failure
E5 m m Power failure
E8 * mm m Voltage supply failure
E9 m Compressor started incorrectly
EA * Incorrect communication with the outdoor unit
EU m * The air conditioner is supplied with an electric current of invalid parameters
EE EEPROM failure
EP No communication between outdoor and indoor units
P0 The unit did not start correctly
P1 Discharge superheat
P2 Increased current in the circuit
P3 Mains voltage too high
P4 mm * No communication with the current relay
P5 Evaporator overheat
P6 Condenser overheating
P7 Matrix protection IPM
* - the diode is lit, m - the diode is blinking.

Error codes for Pioneer air conditioners of the external module:

Pioneer air conditioner error code (number of diode blinks) Pioneer air conditioner error decoding
1 No communication with external temperature sensor
2 No communication with the condenser temperature sensor
3 No connection with discharge temperature sensor
4 Mains current too high
5 Mains voltage too high
7 No communication with indoor unit
9 The unit was not started up correctly
12 Mains voltage too high
13 IPM board protection
16 Compressor over temperature
17 Discharge temperature too high
18 Condenser temperature too high
19 IPM board malfunction
20 Communication error between indoor and outdoor units
22 Deicing

Quattroclima error codes

Error codes for Quattroclima air conditioners (Quattroclima)

Error or task
RUN indicator
Digital
display
Cause and troubleshooting
Switching to defrost mode
Flashes 1 time per second
dF
Is not an error.

Cold air prevention
Flashes 1 time per 3 seconds
Indoor unit fan does not rotate This is not an error.
Service function of the air conditioner and its settings cannot be changed.
Room temperature sensor error
Flashes 2 times in a row every 4 seconds
E2



Pipe temperature sensor error
Flashes 3 times in a row every 5 seconds
E3
1. Check the resistance of the temperature sensor, if the resistance of the sensor is not correct for the current temperature, replace the sensor.
2. Check sensor connection and continuity
3. The control board is defective, replace the board.

Outdoor unit error
Flashes 4 times in a row every 6 seconds
E4
1. Check compressor current and winding resistance.
2. Check the operating pressure. In the event of a refrigerant leak: Remove any remaining refrigerant and repair the leak, evacuate the system and charge according to the scale.
3. Check the outdoor unit pipe sensor.
4. Check the condenser of the outdoor unit, it must be clean, free of dust and dirt.
5. Check the operation of the outdoor unit fan.
6. The control board is defective, replace the board.
Indoor fan control error
Flashes 5 times in a row every 7 seconds
E5
1. Check the connectors connecting the fan motor to the control board.
2. Check the indoor fan motor.
3. Check the control board components for damage. Replace damaged elements or control board.
Internal board error
Flashes 6 times in a row every 8 seconds
E6
1. Check the fan of the indoor unit.
2. Check the output signal from the control board. Replace control board.
Communication error between blocks
Flashes 7 times in a row every 9 seconds
E7
1. Check the interunit electrical connection.
2. Check compressor current and winding resistance.
3. Check the operating pressure.
overheat protection
Flashes 8 times in a row every 10 seconds
E8
1. Check the filters, they must be clean.
2. Check the operation of the indoor unit fan.
3. Check the indoor unit pipe sensor.
4. Check the operating pressure. In the event of a refrigerant leak: Remove any remaining refrigerant and repair the leak, evacuate the system and charge according to the scale.

Samsung Error Codes

Error codes for Samsung air conditioners (Samsung)


E464 - An overload has occurred in the power module.
E461 - it is impossible to start the compressor.
E473 - the compressor has blocked.
E466 - Incorrect voltage in the DC module of the board.
E221 - an error has occurred in the sensor responsible for the outdoor temperature
air.
E416 - overheating detected.
E251 - An error has occurred in the temperature sensor.
E468 - An error has occurred in the current sensor.
E465 - an error has occurred in the operation of the compressor.
E237 - An error has occurred in the temperature sensor winding.
E202 - The time allotted for the connection has expired.
E458 - An error has occurred in the operation of the fan.
E471 - an error occurred in the operation of OTP.
E467 - an error occurred while rotating the compressor.
E469 - An error has occurred in the voltage sensor.
E554 - A refrigerant leak has been detected.
E472 - AC voltage error.
E121 - short circuit in the sensor responsible for the temperature of the indoor air.
E122 - short circuit in the sensor responsible for the temperature of the evaporator.
E154 - An error has occurred in the fan of the indoor unit.
E101 - connection time exceeded.
E186 - MPI error fixed.

Sanyo Error Codes

Error codes for Sanyo air conditioners (Sanio)

E01, E05, E14, E17 - an error occurred when receiving a communication signal;
E02, E04, E06, E10, E20 - an error occurred during the transmission of the communication signal;
E03 - an error occurred in the remote control;
E07 - low power level of the indoor unit;
E08 - there was a duplication of the installation of the addressee of the indoor unit;
E09 - duplication occurred in the control panel setting;
E11 - duplication occurred in the implementation of simultaneous multicontrol operations;
E15 - high power level of the indoor unit;
E16 - there is no connection of the elements of the indoor unit;
E18 - an error occurred in the connection with the MDC;
E31 - errors occurred in the group settings of the indoor unit;
L01 - types of indoor and outdoor units do not match;
L02 - in the group control there was a duplication of the main block;
L03 - there was a duplication of the address in the outdoor unit;
L04 - a group connection has been made for the indoor unit;
L07 - address or group not set;
L08 - power in the indoor unit is not set;
L09 - an error occurred in setting the power of the outdoor unit;
L10 - an error occurred in the connection of the control circuits;
L11 - an error occurred in setting the power of the indoor unit;
L13 - as a result of connection ceiling panel There has been a breakdown;
P01 - malfunctions of the float relay;
P03 - there were problems with food;
P05 - no gas;
P09 - overheating has occurred;
P10 - there were problems with the discharge temperature;
P15 - blocked 4-code valve;
P19 - cooling is overloaded;
P20 - malfunctions of the outdoor unit fan;
P22, P26 - failures in the operation of the compressor inverter;
P29 - errors in the operation of multicontrol when performing simultaneous operations;
P31 - overload in the compressor;
H01, F02 - malfunctions of the temperature sensor of the indoor unit;
F01 - malfunctions of the temperature sensor in the outdoor unit;
F04, F06, F07 - violation of the temperature mode in the outdoor unit;
F08 - violations in the intake temperature mode;
F10 - violations in the discharge temperature mode;
F12, F29, F31 - errors in the internal non-volatile memory.

TCL Error Codes

Error codes for TCL air conditioners (Tcl)

E0 RUN、TIMER –both winking In and out communication failure. No communication between outdoor and indoor units, check interconnection, indoor and outdoor boards
EC RUN、TIMER –both winking Outdoor communication failure
E1 RUN-1 time/8s Outdoor sensor
E2 RUN-2 times /8s Indoor coil temperature sensor
E3 RUN-3 times /8s Outdoor coil temperature sensor Faulty condenser temperature sensor
E4 RUN-4 times /8s System abnormity System abnormal
E5 RUN-5 times /8s Type mismatch
E6 RUN-6 times /8s Indoor fan motor
E7 RUN-7 times /8s Outdoor temperature sensor
E8 RUN-8 times /8s Discharge temperature sensor Compressor discharge temperature sensor
E9 RUN-9 times /8s Invert module abnormity
EF RUN-10 times /8s Outdoor fan motor(DC) Outdoor fan motor
EA RUN-11 times /8s Current sensor
EE RUN-12 times /8s EEPROM failure ROM, firmware failure.
EP RUN-13 times /8s Top of compressor temperature switch
EU RUN-14 times /8s Voltage sensor
EH RUN-15/8 sec Intake temperature sensor

Emergency stop

P1 RUN: Blink; TIMER: 1 blink /8 sec Overvoltage / undervoltage protection Low/high supply voltage
P2 RUN: Blink; TIMER: 2 blink /8 sec Overcurrent protection
P4 RUN: Blink; TIMER: 4 blink /8 sec Exhaust overtemperature protection
P5 RUN: Bright; TIMER: 5 blink /8 sec Subcooling protection under cooling mode
P6 RUN: Bright; TIMER: 6 blink /8 sec Overheating protection under cooling mode
P7 RUN: Bright; TIMER: 7 blink /8 sec Overheating protection under heating mode
P8 RUN: Bright; TIMER: 8 blink /8 sec Outdoor overtemperature / undertemperature protection Outdoor overheat / undertemperature protection
P9 RUN: Blink; TIMER: 9 blink /8 sec Drive protection (software control)
P0 RUN: Blink; TIMER: 10 blink /8 sec Module protection (hardware control)

Toshiba error codes

Error codes for Toshiba air conditioners (Toshiba)


00-0C - an error in the board of the indoor unit or sensor responsible for
air temperature inside the device.
00-0d - an error in the control board or sensor responsible for
radiator temperature.
00-11 - malfunctions in the motor or fan board.
00-12 - repair or replacement of the control board is required.
01-04 - the board or fuses on it burned out, interconnect
installed incorrectly.
01-05 - an error has been fixed in the inverter board.
02-14 - overload detected in the inverter.
02-16 - there was a short circuit in the compressor windings.
02-17 - An error has occurred in the current sensor.
02-18 - an error occurred in the temperature sensors.
02-19 - An error has occurred in the temperature sensor of the board.
02-1A - burned out or blocked the motor or board.
02-1b - a malfunction in the board or sensor responsible for the temperature of the board.
02-1C - the compressor did not have time to start in the allotted time.
03-07 - an error has occurred in the inverter board or a defect has been noticed
coolant.
03-1d - the compressor is faulty.
03-1E - an error has occurred in the sensor responsible for the suction tube.
03-1F - the refrigeration circuit is overloaded or the voltage in the compressor is low.
03-08 - the four-way valve is faulty.

There is "CHEK" on the remote control, press it, point the remote control at the air conditioner and scroll through the codes with the temperature arrows, the air conditioner will produce a signal on the fixed codes. So you determine the error code, and you can also reset it. If the error is not critical.

Zanussi error codes

Error codes for Zanussi air conditioners (Zanussi)

Error codes for indication in the indoor unit
Error code Fault Display indication Remark
E2 Room temperature sensor failure TIMER lamp flashes at 5 Hz
E3 Evaporator sensor fault START lamp flashes at 5 Hz
E5 Condenser sensor fault Defrost lamp flashes at 5 Hz The system will automatically operate correctly after the fault has been corrected
F5 Faulty drain pan float switch Alarm lamp flashes at 5 Hz
F2 Fault in the outdoor unit The defrost and alarm lamp flashes at a frequency of 5 Hz
P6 EEPROM failure START and TIMER lamp flashes at 5 Hz The system will operate normally after complete shutdown.

Indication of error codes in the Zanussi outdoor unit
Fault Indication on the board
Low pressure protection Flashes 4 times every 6 seconds
High pressure protection Flashes 3 times every 5 seconds
Reverse phase protection Flashes 9 times every 11 seconds
Over current protection Flashing 7 times every 9 seconds
Outside temperature sensor failure Flashes 5 times every 7 seconds
Outdoor heat exchanger overheating protection Flashes 2 times every 4 seconds
Defrost protection Flashing 1 time every 3 seconds
EEPROM error Flashes 8 times every 10 seconds