Gas boiler operating instructions. How to start a gas boiler for the first time How to light a dani gas boiler

This article is about how to turn on a Dani boiler with different gas valves.

With coming autumn-winter period Most people are looking for a way to stay warm and heat their home. Most people use a gas boiler for these purposes. After a long period of not using the boiler or when first meeting with a gas boiler, many people forget or do not know how to start the boiler. Many also do not know what to do if the boiler goes out or does not light up at all. But the gas boiler does not light up, most likely due to it being turned on incorrectly. The same thing happened with us. Our apartment has a Dani parapet gas boiler. And I decided to give you small instructions upon launch gas boiler Dani to help you.

Before turning on the Dani gas boiler, it is necessary to ventilate the room for at least 15 minutes.

Subsequence inclusion apparatus (boiler)with gas valveHONEYWELL»

1. Open the door of the device (boiler). Make sure that the control knob is in the position (the device (boiler) is off). Open the tap on the gas pipeline in front of the device (boiler).

2. Turn the control knob all the way (counterclockwise) to the ignition position and press down, hold it pressed for 5-10 s (the holding time that is necessary to displace air from the pilot burner tube), and turn further, without releasing the knob, to the middle position (there should be a click). If the pilot burner lights up, you must hold the control knob pressed for at least 15 seconds and release it smoothly. Then turn the control knob to the position (the device (boiler) is on) to ignite the burner, while the flame on the pilot burner should not go out.

3. The pilot burner may not ignite until gas pressure forces the air out of the pilot tube. If the flame goes out, repeat the operation after at least 1 minute. If for any reason the burner does not light up and the pilot burner goes out, re-ignite it no earlier than after 5 minutes.

4. The temperature of the coolant in the apparatus (boiler) is regulated by turning the temperature control knob to position 1-7. Position 7 approximately corresponds to a temperature of 90° C.

Drawing. Gas valve“HONEYWELL”

Subsequence inclusion apparatus (boiler)with gas valve « EUROSIT»


Drawing. Gas valve "EUROSIT"

1. Open the door of the device (boiler). Make sure that the temperature control and adjustment knob (control knob) is in the position (appliance (boiler) off). Open the tap on the gas pipeline in front of the device.

2. Turn the control knob counterclockwise to the piezo ignition position.

3. Press the control knob all the way and, without releasing it, press the piezo ignition button until it clicks. keep the control knob pressed for 5-10 seconds.

4. Release the control knob and check the presence of flame on the ignition (pilot) burner

5. If there is no flame, repeat the steps, increasing the time you press the control knob.

6. The temperature of the coolant in the apparatus (boiler) is regulated by turning the control knob to position 1-7. Position 7 approximately corresponds to a temperature of 90°C.

Subsequence inclusion apparatus (boiler)with gas valve "ZAO Mashzavod"

ATTENTION! Before igniting the apparatus (boiler), check that the main burner tap is closed

1. Open the door of the apparatus (boiler) and, making sure that valve 3 in front of the burner is closed, open the valve on the gas pipeline in front of the apparatus (boiler).

2. Press the start button 1 all the way and, while holding it, press the piezo ignition button 2 until it clicks. The pilot burner may not ignite until the air is forced out of the pilot burner tube by gas pressure. In this case, press the piezo ignition button several times without releasing button 1 until the pilot burner is completely ignited.

3. After 30 seconds (counting from the moment the flame appears on the pilot burner), release the start button, while the flame on the pilot burner should not go out. If the flame goes out, repeat the operation, no earlier than after 5 minutes.


Drawing. Gas valve JSC "Mashzavod"

4. Open burner tap 3 by smoothly turning the tap handle 90° counterclockwise (the tap handle should be parallel to gas pipe). The main burner should light up. If for any reason the burner does not light up and the pilot burner goes out, then it is necessary to close the burner valve 3 and repeat the operations again, but not earlier than after 5 minutes.

5. Turn the temperature adjustment knob 4 to set the required heating temperature of the coolant in the apparatus (boiler). Control heating using temperature indicator 1. The temperature of the coolant in the apparatus (boiler) is regulated by turning the control knob to position A to E. Position E approximately corresponds to a temperature of 90ºC of the coolant in the capacitive heat exchanger. Mark 5, corresponding to the set temperature position on the temperature adjustment knob, must coincide with mark 6 on the gas valve body.

Thank you, warmth to everyone.

1.
2.
3.
4.

When arranging a heating structure, many homeowners prefer installing double-circuit gas boilers. These heating units when installed modern models They are reliable, they are economical and allow you to provide hot water in the house, but it is important to know how to start a gas boiler correctly the first time.

In order for the device to work for a long time and without repair, you need to properly organize the first start-up of the gas boiler, during which the system is filled with water and the air trapped in them is removed from the pump and heating batteries. In order to facilitate this process For radiators, special devices are used - Mayevsky taps. They should be unscrewed until water comes out of them.

To prevent air from remaining in the pump, first remove the front panel of the unit and perform necessary adjustment. Air pockets are quickly removed, and the equipment automatically starts working.

How to start a gas boiler: preparation

There are simple instructions explaining how to start the gas boiler shown in the photo. The initial start-up is carried out when the installation and wiring of all elements of the heating equipment is completed, and the correctness of the work has been verified by the relevant authorities.

The location of the heating unit must be selected in accordance with safety standards and regulations that prevent fires. The boiler must be located at a certain distance from the wall, which depends on the manufacturer's recommendations. By the way, for some models gas appliances this requirement is not relevant. You should also make sure that there are no flammable materials or objects nearby.

In addition, it is prohibited to place boilers near windows, as their operation will be disrupted. The even position of the device body is of no small importance - even minor distortions are unacceptable.

After installation is complete, begin connecting the equipment to the source. cold water: the plugs are removed from the pipes, and a filter with a ball valve is placed at the inlet. Similar device protects heating structure from all kinds of contaminants that cause damage. Ball Valves must be placed on all pipes used for piping.

Solving the problem of how to start a gas boiler, Special attention should be given to the installation of pipes from the gas main. They do not carry out these installation works themselves, but invite specialists from the relevant services who are involved in connecting, sealing and, if necessary, installation gas meter.

Before you turn on the gas boiler, you should lay a separate power line specifically for the heating unit. Equipment needs to be equipped electric cable with a plug, and install a socket next to the device, separating it from the others.

After this, the boiler is connected to the chimney pipe, in which the draft and its performance are checked. She must go outside. Carrying out installation work chimney installation depends on the type heating device.

When preparing for startup, the boiler is disconnected from the power supply to fill it and the heating system cold water. Then they check for leaks, turn the thermostat to the maximum value so that it lights up automatically
operating mode switch.

Rules for filling the system with water before turning on the gas boiler

Before lighting the gas boiler and turning on heating system, first it is filled with cold coolant, which, after heating, will circulate through the pipes and radiators. During the first launch, everything is carefully checked so that further operation is uninterrupted and the equipment does not require repairs.
The unit body has a special tap located near the pipe to supply coolant to the system. During the filling process, the pressure in the system is monitored thanks to the presence of sensors and pressure gauges. IN modern boilers They are already installed and there is no need to purchase them additionally. When the device is filled with water, the mark on the sensor rises. When it reaches the 1.5-2 atmosphere mark, the water supply is shut off and thus completing the filling.

These pressure parameters can be changed as they depend on the manufacturer's requirements for the operating pressure in the heating system. But filling with cold water does not end there, since replenishment will be required after the structure is freed from air pockets.

Removing air pockets before lighting a gas boiler

Before lighting a gas boiler, you need to fill the heating structure with liquid cold coolant. But just filling with water is not enough. It will either not work, or the degree of heating of the room will be insufficient. A full first start is impossible without releasing the air accumulated in the system. Often in modern gas boilers There is a special system that automatically releases air when filling. But often its effectiveness is insufficient: you will still need to manually reset the air locks. Only after this can you start.

Delete air jams Before turning on the gas boiler, it is necessary not only from the heating unit, the circulation pump, but also from all heating radiators. The process should begin with batteries - for this, as mentioned above, they will be equipped with Mayevsky cranes. They are opened by placing a container underneath. First, a slight whistle will be heard, indicating that air is gradually leaving the system. After removing the plugs, water begins to flow. Then the taps are closed. A similar procedure should be done with each of the radiators. Read also: "".

When air has been removed from the batteries, the pressure gauge needle should point to a certain value. Before lighting the gas boiler, coolant should be added to the system and thus recharged. Read also: "".

After this, the electric ignition of the boiler will work, and the device will turn on independently. The pressure in the system should be adjusted by adding coolant fluid to the required level. The design, gradually warming up, enters the desired operating mode. The effective functioning of any type of heating equipment depends on the correct execution of the stages of preparation, start-up, and adjustment.

How to start a gas boiler, watch the video:

1.How to start a gas boiler: preparation
2. Rules for filling the system with water before turning on the gas boiler
3. Removing air pockets before lighting the gas boiler
4. Useful tips

When arranging a heating structure, many homeowners prefer installing double-circuit gas boilers. These heating units, when installed in modern models, are reliable, they are economical and allow you to provide hot water supply in the house, but it is important to know how to start a gas boiler correctly the first time.

In order for the device to work for a long time and without repair, you need to properly organize the first start-up of the gas boiler, during which the system is filled with water and the air trapped in them is removed from the pump and heating batteries. To facilitate this process, special devices are used for radiators - Mayevsky taps. They should be unscrewed until water comes out of them.
To ensure that no air remains in the pump, first remove the front panel of the unit and make the necessary adjustments. Air pockets are quickly removed, and the equipment automatically starts working.

How to start a gas boiler: preparation

There are simple instructions explaining how to start the gas boiler shown in the photo. The initial start-up is carried out when the installation and wiring of all elements of the heating equipment is completed, and the correctness of the work has been verified by the relevant authorities.

The location of the heating unit must be selected in accordance with safety standards and regulations that prevent fires. The boiler must be located at a certain distance from the wall, which depends on the manufacturer's recommendations. By the way, for some models of gas appliances this requirement is not relevant. You should also make sure that there are no flammable materials or objects nearby.

In addition, it is prohibited to place boilers near windows, as their operation will be disrupted. The even position of the device body is of no small importance - even minor distortions are unacceptable.
After installation is completed, they begin to connect the equipment to a source of cold water: remove the plugs from the pipes, and place a filter with a ball valve at the inlet. Such a device protects the heating structure from all kinds of contaminants that cause damage. Ball valves must be installed on all pipes used for piping.

When solving the problem of how to start a gas boiler, special attention should be paid to the supply of pipes from the gas main. They do not carry out this installation work themselves, but invite specialists from the relevant services who are involved in connecting, sealing and, if necessary, installing a gas meter.

Before you turn on the gas boiler, you should lay a separate power line specifically for the heating unit. The equipment must be equipped with an electrical cable and plug, and an outlet must be installed next to the device, separating it from the others.
After this, the boiler is connected to the chimney pipe, in which the draft and its performance are checked. She must go outside. The installation work to install the chimney depends on the type of heating device.

When preparing for startup, the boiler is disconnected from the power supply to fill it and the heating system with cold water. Then they check for leaks, turn the thermostat to the maximum value so that it lights up automatically
operating mode switch.

Rules for filling the system with water before turning on the gas boiler

Before lighting a gas boiler and turning on the heating system, it is first filled with cold coolant, which, after heating, will circulate through the pipes and radiators. During the first launch, everything is carefully checked so that further operation is uninterrupted and the equipment does not require repairs.

The unit body has a special tap located near the pipe to supply coolant to the system. During the filling process, the pressure in the system is monitored thanks to the presence of sensors and pressure gauges. In modern boilers they are already installed and there is no need to purchase them additionally. When the device is filled with water, the mark on the sensor rises. When it reaches the 1.5-2 atmosphere mark, the water supply is shut off and thus completing the filling.

These pressure parameters can be changed as they depend on the manufacturer's requirements for the operating pressure in the heating system. But filling with cold water does not end there, since replenishment will be required after the structure is freed from air pockets.

Removing air pockets before lighting a gas boiler

Before lighting a gas boiler, you need to fill the heating structure with liquid cold coolant. But just filling with water is not enough. It will either not work, or the degree of heating of the room will be insufficient.

Rules for the operation of gas and solid fuel automatic boilers

A full first start is impossible without releasing the air accumulated in the system. Often modern gas boilers have a special system that automatically releases air when filling. But often its effectiveness is insufficient: you will still need to manually reset the air locks. Only after this can you start.

It is necessary to remove air pockets before turning on the gas boiler not only from the heating unit, circulation pump, but also from all heating radiators. The process should begin with batteries - for this, as mentioned above, they will be equipped with Mayevsky cranes. They are opened by placing a container underneath. First, a slight whistle will be heard, indicating that air is gradually leaving the system. After removing the plugs, water begins to flow. Then the taps are closed. A similar procedure should be done with each of the radiators. Read also: “How to choose a Danko boiler - types of heating gas boilers, features, advantages.”

When air is removed from the batteries, the pressure gauge needle should settle at a certain value. Before lighting the gas boiler, coolant should be added to the system and thus recharged. Read also: "How to turn on the Lemax boiler - operating rules."

To eliminate the plugs that have accumulated in the circulation pump, partial disassembly of the boiler will be required. This work is not difficult: you need to remove the front panel from the device, then find a cylindrical element that has a cover in the middle of the body with a slot for a screwdriver. Read also: “What is good about the Conord gas boiler - characteristics, advantages, types.”

To start the boiler, it is necessary to supply power and set the heating regulator to the required operating position. The presence of a weak hum indicates that it has started working circulation pump. Using a screwdriver, lightly unscrew the cover on the detected part. But this must be done before the water begins to flow. If liquid begins to seep out, screw the cap back into place. Such actions are performed several times and after this the air pockets will be completely removed from the system. The gurgling sounds will also disappear and the pump will run quietly. Read also: “Advantages of the Navien gas boiler - characteristics.”

After this, the electric ignition of the boiler will work, and the device will turn on independently. The pressure in the system should be adjusted by adding coolant fluid to the required level. The design, gradually warming up, enters the desired operating mode. The effective functioning of any type of heating equipment depends on the correct execution of the stages of preparation, start-up, and adjustment.

How to start a gas boiler, watch the video:

How to start a gas boiler for the first time

How to start a gas boiler

How to start a wall-mounted gas boiler

Starting the unit

Before starting a wall-mounted gas boiler, you must ensure that the following conditions are met:

- make sure that the gas pipeline is tight when the valve on the device is closed and then open for a period of time that exceeds 10 minutes, during which the meter should not register any gas consumption;

— make sure that the type of gas used matches the boiler settings;

— turn on the boiler and make sure that it is properly ignited;

— make sure that the gas flow and gas pressure correspond to the data given in the instructions;

— check whether the unit is blocked by air/flue gas flow;

— make sure that the concentric intake/discharge terminal or chimney channel was not covered by foreign objects.

The machine should not be started if any of the above conditions are not met.

The first start-up of the device should only be carried out by service personnel.

Switching on the wall-mounted gas boiler for the first time

The first switching on must be carried out exclusively by a specialist, which is a prerequisite for warranty service and is the key to maintaining best qualities device: reliability, efficiency and economy.

Starting the boiler - checking the first start

To start a wall-mounted gas boiler, you need to check:

— tightness of the gas supply circuit with the shut-off valves closed, and then with the shut-off valves open and the gas valve turned off (closed); for 10 minutes the meter is not intended to record gas consumption;

— compliance of the available gas and the gas with which the unit must work;

- connection to a 220 V - 50 Hz network, matching L-N polarity and grounding;

- in order for the heating circuit to be completely filled with water, the pressure gauge needle should show a pressure value of 1-1.2 bar;

— that the air release valve cover is open and that the system is completely free of air;

— correct switching on after starting the boiler;

— so that the maximum, average and minimum gas supply and the corresponding pressure correspond to the passport data;

- triggering safety device when the gas supply stops and the response time;

— operation of the main switch of the device;

— so that the air intake and exhaust pipes of combustion products are not clogged;

— operation of the smoke pressure safety switch in the absence of draft;

— work of regulatory bodies;

— gas supply control devices (if changes have been made to their settings);

— boiler operation in DHW mode;

— tightness of the hydraulic circuits of the device;

— ventilation of the room where the device is installed.

If at least one of the safety checks gives a negative result, the boiler unit cannot be turned on.

How to turn on a wall-mounted gas boiler

Before turning on the wall-mounted gas boiler, you need to check the pressure in the heating system; the pressure gauge needle should show a value of 1-1.2 bar. If necessary, top up the heating system.

— Open the gas valve at the boiler inlet.

— By pressing the button, set the boiler to the desired mode, the temperature is adjusted using the setting buttons.

Having selected the heating mode, the temperature of the coolant in the heating system is adjusted using the setting buttons. When you press “+” the temperature increases, and when you press “-” it decreases.

From this moment on, the boiler operates in automatic mode. If there is no heat demand (heating or production hot water), the boiler enters the standby state, that is, the device is supplied with power, but there is no flame. Each time the burner is ignited, the display shows the corresponding flame presence symbol.

Ignition blocking. If it is necessary to operate the boiler in heating or hot water mode, the burner is automatically ignited. If the burner does not ignite within 10 seconds, the ignition is blocked.

To remove the lock, you must press the restart button. When you turn it on for the first time or after long downtime unit, it may be necessary to remove the ignition lock due to the presence of air in the gas line.

How to start a floor-standing gas boiler

Preparing and starting the boiler

Before starting a floor-standing gas boiler, it is necessary to carry out following works:

— Let's fill the heating system with water. Let's check the water pressure on the boiler pressure gauge.

— We will check the connection of the device for the removal of combustion products.

— Let’s open the gas supply valve and let gas into the boiler. Let's measure the pressure at the inlet to the boiler.

— We will de-air the gas connection.

— Let's press the power switch. The boiler will turn on and heat the DHW. After heating it, it switches to the heating system. While the boiler is operating, we check the tightness of all gas path connections in the unit with a soap solution. Possible leaks (arising, for example, during transportation) must be eliminated and the inspection repeated.

— At the end of preparation and startup of the boiler, it is necessary to carry out control, if necessary, change the boiler power by setting the gas pressure at the outlet of the gas fittings.

The setting is carried out by the control elements on the combined gas fittings.

Before turning on the floor-standing gas boiler:

- ventilate the room for at least 15 minutes;

— check whether the taps are closed;

- check the draft in the chimney by placing a lit match near the draft breaker door. During normal draft, the match flame will be drawn into the draft breaker.

Steps to turn on a floor-standing gas boiler:

— Open the unit door. After making sure that the temperature control and adjustment knob (control knob) is in the off position, open the tap on the gas pipeline in front of the device.

— Turn the control knob counterclockwise to the piezo ignition position.

— Press the control knob all the way. Hold the control knob pressed for 5-10 seconds (the time required for the gas to displace air from the pilot tube). Press the piezo ignition button until it clicks.

— Release the control knob and check for flame on the ignition (pilot) burner.

— If there is no flame, repeat ignition, increasing the time you press the control knob.

— Turn the control knob to the desired position and make sure that the main burner is working. The temperature of the coolant in the device is adjusted by turning the control knob.

__________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

Protherm Panther Protherm Stingray Protherm Bear Protherm Cheetah Evan
Ariston Egis Teplodar Cooper Atem Zhitomir Neva Lux Arderia Nova
Termona Immergas Electrolux Conord Lemax Galan Mora Aton Boiler models Boiler repair tips Error codes Service instructions

Installation and operation of gas boilers Bosch 6000

Management and maintenance Vaillant boilers Turbotec / Atmotec

Review of gas boilers Zhytomyr-3 Atem

Installation of a heating system for a private house

Boilers Danko, Ross and Dani - Experts' answers to user questions

Review solid fuel boiler Cooper OK-15 Teplodar

Malfunctions and errors of Ferroli boilers

Assembly elements, installation and connection of the Skat Protherm electric boiler

Review of heating boilers Don KST-16

Repair and service of Vailant boilers - expert answers

Review of the KSG Ochag gas boiler

Review of the heating boiler Cooper OK-20 Teplodar

Equipment and components of the electric boiler Proterm Skat

Connection and commissioning of the Buderus Logomax U072 boiler

Answers from specialists on boiler malfunctions Kiturami

Advice from experts on servicing Navien boilers

Maintenance of Navien Deluxe gas boiler components

Connecting the Ariston Egis Plus 24 ff boiler to working systems

This article is about how to turn on a Dani boiler with different gas valves.

With the arrival of the autumn-winter period, most people are looking for a way to stay warm and warm their home. Most people use a gas boiler for these purposes. After a long period of not using the boiler or when first meeting with a gas boiler, many people forget or do not know how to start the boiler. Many also do not know what to do if the boiler goes out or does not light up at all. But the gas boiler does not light up, most likely due to it being turned on incorrectly. The same thing happened with us. Our apartment has a Dani parapet gas boiler. And I decided to give you a little instructions on how to start a Dani gas boiler to help you.

Before turning on the Dani gas boiler, it is necessary to ventilate the room for at least 15 minutes.

Subsequence inclusion apparatus (boiler)with gasvalveHONEYWELL»

1. Open the door of the device (boiler). Make sure that the control knob is in the position (the device (boiler) is off).

How to light a Dani boiler

Open the tap on the gas pipeline in front of the device (boiler).

2. Turn the control knob all the way (counterclockwise) to the ignition position and press down, hold it pressed for 5-10 s (the holding time that is necessary to displace air from the pilot burner tube), and turn further, without releasing the knob, to the middle position (there should be a click). If the pilot burner lights up, you must hold the control knob pressed for at least 15 seconds and release it smoothly. Then turn the control knob to the position (the device (boiler) is on) to ignite the burner, while the flame on the pilot burner should not go out.

3. The pilot burner may not ignite until gas pressure forces the air out of the pilot tube. If the flame goes out, repeat the operation after at least 1 minute. If for any reason the burner does not light up and the pilot burner goes out, re-ignite it no earlier than after 5 minutes.

4. The temperature of the coolant in the apparatus (boiler) is regulated by turning the temperature control knob to position 1-7. Position 7 approximately corresponds to a temperature of 90° C.

Drawing. Gas valve “HONEYWELL”

Subsequence inclusion apparatus (boiler)with gas valve« EUROSIT»

Drawing. Gas valve "EUROSIT"

1. Open the door of the device (boiler). Make sure that the temperature control and adjustment knob (control knob) is in the position (appliance (boiler) off). Open the tap on the gas pipeline in front of the device.

2. Turn the control knob counterclockwise to the piezo ignition position.

3. Press the control knob all the way and, without releasing it, press the piezo ignition button until it clicks. keep the control knob pressed for 5-10 seconds.

4. Release the control knob and check the presence of flame on the ignition (pilot) burner

5. If there is no flame, repeat the steps, increasing the time you press the control knob.

6. The temperature of the coolant in the apparatus (boiler) is regulated by turning the control knob to position 1-7. Position 7 approximately corresponds to a temperature of 90°C.

Subsequence inclusion apparatus (boiler)with gas valve "ZAO Mashzavod"

ATTENTION! Before igniting the apparatus (boiler), check that the main burner tap is closed

1. Open the door of the apparatus (boiler) and, making sure that valve 3 in front of the burner is closed, open the valve on the gas pipeline in front of the apparatus (boiler).

2. Press the start button 1 all the way and, while holding it, press the piezo ignition button 2 until it clicks. The pilot burner may not ignite until the air is forced out of the pilot burner tube by gas pressure. In this case, press the piezo ignition button several times without releasing button 1 until the pilot burner is completely ignited.

3. After 30 seconds (counting from the moment the flame appears on the pilot burner), release the start button, while the flame on the pilot burner should not go out. If the flame goes out, repeat the operation, no earlier than after 5 minutes.

Drawing. Gas valve JSC "Mashzavod"

4. Open burner tap 3 by smoothly turning the tap handle 90° counterclockwise (the tap handle should be parallel to the gas pipe). The main burner should light up. If for any reason the burner does not light up and the pilot burner goes out, then it is necessary to close the burner valve 3 and repeat the operations again, but not earlier than after 5 minutes.

5. Turn the temperature adjustment knob 4 to set the required heating temperature of the coolant in the apparatus (boiler). Control heating using temperature indicator 1. The temperature of the coolant in the apparatus (boiler) is regulated by turning the control knob to position A to E. Position E approximately corresponds to a temperature of 90ºC of the coolant in the capacitive heat exchanger. Mark 5, corresponding to the set temperature position on the temperature adjustment knob, must coincide with mark 6 on the gas valve body.

Thank you, warmth to everyone.

D 20 Power: 19.50 kW Dani Forte 25 Power: 25 kW Dani Comfort 11.5 Power: 11.50 kW Dani Comfort D 11.5 Power: 11.50 kW Dani Comfort 18 Power: 18 kW Dani Comfort D 18 Power: 18 kW Dani AOGV 7 .4 C Power: 7.40 kW Dani AOGV 12 C Power: 12 kW Dani AOGV 7.4 U S Power: 7.40 kW Dani AOGV 12 U S Power: 12 kW Dani AOGV 16 U S Power: 16 kW Dani Beaver Base 12 Power: 12 kW Dani Beaver Base 16 Power: 16 kW Dani Beaver Base 20 Power: 20 kW Dani AOTV 12 Power: 12 kW Dani AOTV 16 Power: 16 kW A service error occurred: Error calling GET https://www.com/youtube/ v3/search?part=snippet&q=%D0%9A%D0%BE%D1%82%D0%BB%D1%8B+%D0%BE%D1%82%D0%BE%D0%BF%D0%BB%D0 %B5%D0%BD%D0%B8%D1%8F+Dani&maxResults=1&key=AIzaSyCbwDKMv_2zqSriJOyPkTt5gTOKGvDuiJc: (403) The calling IP address 2a01:4f8:140:239a::2 does not match the IP restrictions configured on the API key.

How to light a dani boiler

БтДс ЖD@ыB8hУ▐Hl2Д┬DPD-Д6╖ьъ!╘\├43▒жПН~ BDDШЧДИ(!t4ш╡Ъ, ┤╞┐кd\bkъГw╘шсDe╜<╨юфїЄ▌ЖP-B┘,Flп╚Щl7^Дд╩В!!Ц╢:┤┘EСчRЦUУcЖ(ИUВШ░?Д┤ЇЕ}у `┤-Д╨Ж╬$в Д╨o\:╥Mh▀■f┐3 Д·Bf!@(U!ЪЮ: е║H!▀╜╟|Y╧▐■╧╒╣Щ╦єЛЯ-F═% дIшrДЦ╧ь,!║H!d°у┬№В▒zq»rЧCAшЬ!d!б3 Д~╩╗№ОRcOK¤ф┘_ ╫ь-█[бEHЇ╞7бю╖B,ыlЎBeЦM $М@єzЩ@h!╬╪&■сBM 4╓ъ@√Ў·XAhчI_╓уЭWч/╧╧6БP%ДNЯ=їМhєG╩Оёщая=ё│Ч▐ЬЪ╗m{!`Аmф▒=:]A/Ч ╤;)∙\Н VЫф%9ф°Dh3#ЯХР╗cуЄ нqнж &├мQ!Q%Ch═уеBdЗ╨║Ks╝ЄB1╥A’!▄хWCy(eС!╧а:їz╘BQ╩X▒oв╗t yйmU9╚0°Б;XS╝гДйЭ3╫ЛФЗz#kШ,Др╬H!ФKЗ б▓+·p╤│v=бfЬlОхV╚ЎЩ5у%эVAhяф!ш╤Bшоx8ЇФът╒(bCм&}4 !№ц| ┤пEЗP~ГLф!д1╚m╪№Фхз.5^бГ#eК)7ЬЄ┤oп╕пE!zшЗ@ЗpнЮ║lб╕╞ Ў├чєsPWчц╡еЕ┼┼%б9╞9BЛъ!╘╨gChfЦ╙hI╚ии░Гv@Bш╝М3ЖР бO:;0Д┤╤Hhъв═?-<╞-=∙№я▐·`┴Cиi╤ ╝ ё╞T=о:Qр▌C▐╨OC╛ hХx|╤╓щэ8юХгс╥╜▓F╗┌╢ээ│ИЙЪK╩щ│Хж█~+e├#{\GQТПЦЪRN┴яь√?%8▌┤o/8їvvЫ╖{Яf09 oo▄а,!Y▓лчсnp╨╬oбоЫ╖о_╜rei╔Kh╬Зз°┼№|└їЎГ +р ў:((rш┬∙`Шsg╧тD1ьДчi╪йg!|&xщ$╠3=$ЇЬvЪ·╡hє╖GиОёЛ#BO¤Є╒┐Ov╟6 Д╓в$╝I»;0XВ^▐ЗD╙M!d6DBХ н·pЙi═Ш▀кД└RfAXж│%»(╠Q!┤.

Heating boilers dani

A┴Et&┼S╨╔ябd╙:rв9▓OR▄ED╚`QyiQ=Д▄┬╪@bo B5i╒У° dШИ&WcгtHз& !KTV▓RDDER ╦!aIl!H╡ъ#╓BR&»B]SHUyЇ lV ╛ ╔5ДРФбъЦ&─u\/i=v q╣шыЄБНЛж╗╬7Р▓$?Д`дД╠│iД2│еC(eQД┤оfyеPEяДлВРK╞]-╤вН╡и╘.+┬╝GAЎW ╩╕ёN ▀ИR@pcК' TO:gB∙b┬;a╜K Жqь┐hf·AlD|&yo»╚╒Ая^Зs╦┌/Pj9zJК6L╬ж▀╝╘┘%Z_Тш∙▀бI▄■.ўNЗf-с╥%аzwel7 \В° ГL╛└сЯУєЗ╡ Жны√√╗Bў»mln5#Ez└ ─┤╒d»Г[╫ИВНББД, ФБ┐°wЭ.Ш(▄чo█С│╜G╦ы█;A█H(cX№д @ш9д·┘┴еРБИРДрж╡И╫A╤еVT8Pg╝fzICBHbGZHE`' B o╥-D fЎB╤lv_BЪ,R!╘schv,vg'║ByL╓Ta`рJшl№RШ┘W/$╥е1w ШXgjee D№к !─'TбsTQЇМ8H▌╙@╕AпF9д╦fЪН╘e┘a╞╠lY)╚╞╦лГ:┤Bc▄%╧b1/b─│┬ФE∙█Ў▒я║KТ▒ЛзEИН╩ A╚нШjm<зВэГыДJлBИШяСбiq9’°!ОgBH╜W№▌─∙ ╤/bб│╙■Пб░╜▌Э’█═їFcum}├Hи∙0rPЭКЖлВPьаJ d▓оX }№БFЭ.Щ{,ЙєЯ█СAы╔fєЛGm?Дp0vAк_ФЕРНrЄч-ХГPчц@ИеeB+ч!Ъ▄▐!д%╕~ F┌К+А╨∙АЧЬ!╗ёB╡@╚їк░P=е╚/6╗йЪ.

Adjusting the automation in the gas boiler AOGV-18 dani comfort

If for any reason the burner does not light up and the pilot burner goes out, then it is necessary to close the burner valve 3 and repeat the operations again, but not earlier than after 5 minutes. 5. Turn the temperature adjustment knob 4 to set the required heating temperature of the coolant in the apparatus (boiler). Control heating using temperature indicator 1. The temperature of the coolant in the apparatus (boiler) is regulated by turning the control knob to position from A to E.


Position E approximately corresponds to a temperature of 90ºC of the coolant in the capacitive heat exchanger. Mark 5, corresponding to the set temperature position on the temperature adjustment knob, must coincide with mark 6 on the gas valve body.

Gas boiler Dani AKGV 12 s

ShbZfg╩irZh~/ dXzh╩╙F╚·A╝DYF─rS5O╟╚cХ)d:;УУ┤│▄S, Ts╦╤zfXcd-N╔eFRl╚┬iAC7Pp,6E╕iDVLts═vSh'X═y ╞└(S·JTSSHYeMVZMCSHdY│b&╢ГCk5ХeL╟И╔е%l9с+qNГ·y;QT;н%╝%H%Y╬Kў─d(yБ,Б╟pfJИYо JiVСзеы(п'EF╫▀\Шшшro 1O ╘─YЦЎ╬В^╪k Ъ╠дОishk .D\ДЄ╥ШСД╟Xz╒s@рвj╔пjI└п6╓4╓Ф|mFсАzкжЭоФб╢╫sВ& яь╪Цт'╖ШЧВ╠┘W+Qнй └`╠ ╨М┴(-╟п`Л°U╜A J N \╛П;s▒М▐ i&█Sл@_├А) mYeNР№ьWв@,НерШJШю░f│Tk-тЄD╔%К"»r2╚ d┼Q╓b╩ZLєД╞Hчb═пШ·ЪкL▄D╙lYo┌g»ASof,7=T6е·ўП╔y╫i║rНж=]┐вьP2tДy·b█№Vмь BOSHTSIA╘d@EL`d▀ nShb╞ Q╠┤╬ed\5(Chy@Ъm*0vCaULъ;Уєpyь╞╤2noо┤LZ/mЧNq┬█▄шKЪr9RMk'їSc╓Iы╣нR-ў║dJР╙№В╤Є rzR│ff┼HP DWYй╔бV12v ╞╒eyA(┴N»вш#ьWlA▓─v$_ьM4е2NF]$IьE║IPL╧LTgf9-■MLY$[ь!NI/Б┘ИI╤+t ╚@│k╪╛ I9vъЗ╖ZrЯ],у^ ╜▄Shchy╒ r#zBP╪PzZ╕T_)n2p▓RЛV╔&·▓|╙fjqk)Ъ(](-4╧│╬u,t-p/Ё.Ё═ШE !рv\Я; : єГРiН( DT╘Dr$yo▌I»Do*!ДV╦вл)ШЛМЧаНХоmBиВПдЄ╝!$зb└]!(Hyu═▀Д╣mє~a&3BJуVgЕ╨yam╧N:З╧ЯшТти9╢ЪxШШ~@t─wАТ0Г:О6@ e(ОPP)╝p╫тGеA(НJ`ьъ5╓(вVхLAT,NQўфYьk▀Aich ·kИ9╩U кВ4сё┴ИГ┐@Ц┘▓╝░(!▄д!|68У┘∙yuЇ╒yuBdb╛▐CdКUГ ╠╧ b65Гs╔&╞╡Є╥S╠sh.!s/iA┌lBes╘`f▀╝Yu∙╪f╜r-M┴▄v~┐Gу(=# s·zhi)lК╥w√Я8EяC[╜nчУзП7- ДJ уь╤P╫В▄Ъ▌Джb╢╢МфAhs█E╣qbviяс(VYq√рX]]¤╛7▐wН╢╟П°A)Q_┐t║0ьk%C╚■B¤─2ш╕ BШAB╟ B*B*;iI┴╜█Ж^iЗ╓1Р╫ Im_s(╠!`B╒F=╣Ж^xh╤AD*Bi╡┘ $ШЭдшрС∙OSCH)╩°gP╡уж┤iТ─█лJ' @╚┼f#Ш█~o?kFУY 4^iХeiaB°#B)╨lZЯу╟┴╙%еe@иJАН@╚mlBO;kEкНDн№╨Г╨■»╡╤т°?ипьы╫╟БL┘Я▄ _'Bi│Д╙╟BKСXB(JК[VRkYzht%D№Мl▐kД|l,!─oNkAHзOh╘ьd╖suДP_УШ█▐B═s%ЭПфPmг╕eT_╒9▄;уA╚~▐ш╧╥'╨ ╓╗ BPmmmoyav╤ДЁХЗVB(mqЛ»0┌йuЪ,el╘АPiУ=х┐ыфb%ДVV~ъAhuБ╪hsxїО╛О!╘;)9Rс b┐╡gN!d┴u#О-.x╖ч(Х@ gyЛUb3╨Р∙СЛЯАЗРSКОИBH┌I╤CWЛIбV) EE█Ц┌/y░GBB/╠йRК.

Dani boiler instruction manual

It may be necessary to adjust the main burner, how should this be done, can it be adjusted while the boiler is running? Answer: Perhaps the knocking occurs due to thermal expansion of the metal of the heat exchanger. Cracking is the result of scale and deposits that have formed. Question: Ross double-circuit boiler 26ntd - E8 pops up.
What does it mean, I can’t decipher the error? Answer: The DHW sensor does not work. Question: Please tell me about the Ross boiler. The automatic equipment is Eurosit 630. The problem is the following: when you turn off the main burner, it does not go out completely, it burns itself slowly.

Please tell me, is this normal? Answer: Quite normal. The main burner goes out when the set temperature is exceeded. Before this, the bellows covers the burner in order to save money and maintain the set value.

Question: Boiler AOGV Dani.

Important

Go to the catalog Gas boilersDANI: Double-circuit:

  • Gas boiler DANI AKGV 12 C

You can buy a gas boiler DANI AKGV 12 C using one of the offers Yandex.Market data Store Rating Price Delivery All offers DANI AKGV 12 C on Yandex.Market Features of the gas boiler DANI AKGV 12 C Gas boiler DANI AKGV 12 C Parapet boilers DANI AKGV 12 C are designed for heating and hot water supply of apartments in multi-storey buildings, individual residential buildings, residential, administrative and industrial premises with a volume of up to 450 m³. The main design feature of the DANI AKGV 12 C parapet boiler model is a combustion chamber isolated from the room that does not use the air of the room in which the boiler is installed. This heating boiler is equipped with a slot-type (modular) heat exchanger.

I set the desired temperature. At a given temperature (for example, 60 degrees), the automation (Kare) turns off the device, then when the set temperature drops, the automation starts it up again. Periodically (at different times, about once a week) the boiler stops starting automatically (the temperature dropped to 17 degrees, but for some reason the boiler did not turn on? After you turn it off and start it “manually”, the boiler works fine, maintains the set temperature again for some time. What needs to be checked, cleaned, purged, changed in order for the boiler to work properly???

Question: Danko boiler, automatic Kare. Sometimes the boiler heats the water to boiling and goes out. And it doesn’t want to switch from the wick to the main torch until you release the tube that goes to the temperature regulator a little from the reducer.
Press the start button 1 all the way and, while holding it, press the piezo ignition button 2 until it clicks. The pilot burner may not ignite until the air is forced out of the pilot burner tube by gas pressure. In this case, press the piezo ignition button several times without releasing button 1 until the pilot burner is completely ignited.
3. After 30 seconds (counting from the moment the flame appears on the pilot burner), release the start button, while the flame on the pilot burner should not go out. If the flame goes out, repeat the operation, no earlier than after 5 minutes. Drawing. Gas valve JSC "Mashzavod" 4. Open burner valve 3, to do this, smoothly turn the valve handle 90° counterclockwise (the valve handle should be parallel to the gas pipe).


The main burner should light up.
This can be done as follows: - Remove the thermal cylinder from the boiler sleeve. - Take two jars of water, an electric boiler for a glass, a thermometer with a maximum temperature of more than 100 C. - Place an electric boiler for a glass, a thermometer and a thermal cylinder in one jar of water. By turning on the boiler and heating the thermal cylinder to a certain temperature and then by cooling (for example, by removing it from a jar of heated water and lowering it into a jar of cold water, check (repeatedly) how the gas valve will operate. - If it works normally, then you need to check how contact is ensured the walls of the thermal cylinder with the wall of the glass (where it is inserted) in the boiler.

It may be necessary to adjust the main burner, how should this be done, can it be adjusted while the boiler is running? Answer: Perhaps the knocking occurs due to thermal expansion of the metal of the heat exchanger. Cracking is the result of scale and deposits that have formed. Question: Ross double-circuit boiler 26ntd - E8 pops up. What does it mean, I can’t decipher the error? Answer: The DHW sensor does not work. Question: Please tell me about the Ross boiler. The automatic equipment is Eurosit 630. The problem is the following: when you turn off the main burner, it does not go out completely, it burns itself slowly. Please tell me, is this normal? Answer: Quite normal. The main burner goes out when the set temperature is exceeded. Before this, the bellows covers the burner in order to save money and maintain the set value. Question: Boiler AOGV Dani.

How to light a dani boiler

This can be done as follows: - Remove the thermal cylinder from the boiler sleeve.


Attention

Take two jars of water, an electric boiler for a glass, and a thermometer with a maximum temperature of more than 100 C.


Place an electric boiler for a glass, a thermometer and a thermal bulb in one jar of water.
By turning on the boiler and heating the thermal cylinder to a certain temperature and then by cooling (for example, by removing it from a jar of heated water and lowering it into a jar of cold water, check (repeatedly) how the gas valve will operate.

If it works normally, then you need to check how the contact between the wall of the thermal cylinder and the wall of the glass (where it is inserted) in the boiler is ensured.

404 not found

The wick burns and does not light the main burners, and when it boils, it goes out completely.


Important

Tell me what to do? Answer: The main burners turn off when the specified temperature is reached.


Causes: contamination of the impulse (connecting) tubes between the membrane valve and the thermostat, jamming of the remote sleeve of the thermostat.

When the water temperature reaches 50-90 C, the boiler turns off completely (all): adjust the boiling sensor, there is no draft in the chimney.

Question: As soon as I fully tighten the bushing on the diaphragm valve, the boiler does not ignite, but as soon as I loosen it a little, it works and leaks gas a little.

What to do? Answer: Unscrew the screw and remove the handle. Unscrew the screws and remove the scale.

Info

Unscrew the screws and remove the thermostat cover. Remove the membrane assembly without damaging the membranes.


Remove the assembly by the valve mounting screw. Remove the spacer bushing.

Adjusting the automation in the gas boiler AOGV-18 dani comfort

Press the control knob all the way and, without releasing it, press the piezo ignition button until it clicks.
keep the control knob pressed for 5-10 seconds. 4.

Release the control knob and check the presence of flame on the ignition (pilot) burner 5.

If there is no flame, repeat the steps, increasing the time you press the control knob.

6. The temperature of the coolant in the apparatus (boiler) is regulated by turning the control knob to position 1-7.
Position 7 approximately corresponds to a temperature of 90°C.

Sequence of switching on the device (boiler) with the gas valve "ZAO Mashzavod" ATTENTION! Before igniting the apparatus (boiler), check that the main burner tap 1 is closed.

Open the door of the apparatus (boiler) and, making sure that tap 3 in front of the burner is closed, open the valve on the gas pipeline in front of the apparatus (boiler).
2.

Gas boiler Dani AKGV 12 s

Question: Boiler Ross AOGV-11, on the street -10, while the gas consumption is about 20 m3/day.
Private house 80 sq. m. The boiler is on 2, the temperature in the house is approximately 23 degrees.

I thought the consumption should be less. Or I'm wrong? Answer: Gas consumption can be checked this way: set the automatic to the maximum, that is, use the gas meter to measure the consumption per minute, then multiply the consumption per minute by 60.

We check the technical characteristics of the boiler and see if we fit in or not.

Depending on the costs, we either adjust the pressure on the gas valve or not.

Question: I have a 16 kW Ross floor-standing boiler. When heating and cooling, a loud knock (clicking) is heard with a frequency of about 3 seconds, inside at the bottom left, all fasteners are tightened.

Dani boiler instruction manual

IiQиr Ж И+╚& H, Жe╛ЭY^Аы(╨н+h,¤ч∙L` L┌╖йУйjO╒╢ЭAR6╖Шф─мъф!9є╠┼АBpзЭПТДЭз┬П╬(┐mгT╞═ИИў ╝K▀e(тT┤╧дХЄJЛ░ППхХ?tXХ»Z┐ШСкмTO(┬хg%┬╖J°Рne╤е8К&╞Hl┼dпмшХ8ЦSfя╡Sеу╨pX8sBkq4i└ gG·t°цS0с╓ўш ДХ-0ус█╨Н╬ ╥;a=/╝└t▒u∙dгв°lme╢╓]ЦЦОш'╢я-▀)нЦVЗд*┤зхХ#(L(!E╔pa2╛┬p /i▀┬+fxМ°уу╣1кJ╖ ∙PEEES*k═╒╤hXagШB╙M)~╣wpПYCtли╜qн╪4╠╕(┘┌╗#СЎ╒hЪ@╥ИD┌╫R▒т;t╔%Сo┼е#ТЭНЇSуK┘Ъ ┬╨╛ )│оЭ╨ГЎ╚Bj &s─┘KACj[▓wt3ЕЎEQ╘YИ╙&f╦Хь+╥ТЁW╜!gє(╨eеc╫]~9|2ь^iО%3n┘╝ъZ=╜╕д╦Їх3+ў ┘╜_█Ёоц┘r╣f(°4\3v╘ьШ╫TM├╓ыFu▐kagMeYA╨╧dZI╟╦MI,ъРоаш=Ї 6|)[(╡╦7╦╦шЗЇ░Сх:╧3Нж╚ ЇO╣┼BC ┬ 6▀»T╥∙bЛР@╜ВОуО&Ё█евd1┘bIе╠ГЎ╛ Кй╤]+h¤з*─гРжр╡Y($Д*Ц,Л$йЦ,AyUCivНG#ЁИ─ОН░ єИ─Р▀ж^ы─ЪПрПИвSжJ^┼+HVьжhlLkцЎ_tUг╨YXр,╠)/#\gЦ╡чЛ-hЛУ-╛eoWЪ`Z7е8J#Мжb╧,Тєе@╤▀И(*√bPjуИ.БЁ%:р ╗ ╢r°Ў░┬┬╟Ў╖ +6╢^╧V№╒PniEK\m╬E\@Liodj/∙бvЕ+HВб╫ИL│#╤9чц.╢▄▓W╢he√)╦ИТ╜ ¤╝ъ2еЯ)